Worked example
Example: Hugot example: quadruple 120/111/100/85/55. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Clear juice to the evaporator | 100.00 t/h |
| Clear juice brix | 13.000 % |
| Syrup brix | 65.000 % |
| Number of effects | 4.0000 - |
| Dessin factor | 0.001000 - |
| Heating steam temperature (effect 1) | 120.00 °C |
| Vapour temperature leaving effect 1 | 111.00 °C |
| Vapour temperature leaving effect 2 | 100.00 °C |
| Vapour temperature leaving effect 3 | 85.000 °C |
| Vapour temperature leaving effect 4 | 55.000 °C |
| Vapour temperature leaving effect 5 | 55.000 °C |
| Boiling-point rise in effect 1 (brix and head) | 0.80000 K |
| Boiling-point rise in effect 2 (brix and head) | 1.3000 K |
| Boiling-point rise in effect 3 (brix and head) | 2.1000 K |
| Boiling-point rise in effect 4 (brix and head) | 6.1000 K |
| Boiling-point rise in effect 5 (brix and head) | 6.1000 K |
| Vapour bled from effect 1 | 11,204 kg/h |
| Vapour bled from effect 2 | 3,515.0 kg/h |
| Vapour bled from effect 3 | 6,050.0 kg/h |
| Vapour bled from effect 4 | 0 kg/h |
Applying the formula below gives:
| Result | Value |
|---|---|
| Total evaporation | 80,000 kg/h |
| Vapour to the condenser | 10,904 kg/h |
| Evaporation of effect 1 (= heating steam, Rillieux) | 31,673 kg/h |
| Evaporation of effect 2 | 20,469 kg/h |
| Evaporation of effect 3 | 16,954 kg/h |
| Evaporation of effect 4 | 10,904 kg/h |
| Evaporation of effect 5 | 0 kg/h |
| Brix leaving effect 1 | 19.026 % |
| Brix leaving effect 2 | 27.164 % |
| Brix leaving effect 3 | 42.066 % |
| Brix leaving effect 4 | 65.000 % |
| Brix leaving effect 5 | 0 % |
| Heating surface of effect 1 | 696.82 m² |
| Heating surface of effect 2 | 481.39 m² |
| Heating surface of effect 3 | 436.96 m² |
| Heating surface of effect 4 | 316.72 m² |
| Heating surface of effect 5 | 0 m² |
| Total heating surface | 1,931.9 m² |
Open this example in the calculator and change any input.
Formula
\(E = J\left(1 - \frac{B_0}{B_s}\right) = n x + \sum_{i<n} i P_i, \quad q_i = x + \sum_{k \ge i}P_k, \quad B_i = \frac{B_0 J}{J - \sum_{k \le i} q_k}\)
\(b_i = \frac{B_{i-1} + B_i}{2}, \quad c_i = f(100 - b_i)(T_{i-1} - 54), \quad \Delta_i = T_{i-1} - T_i - d_i, \quad S_i = \frac{q_i}{c_i\Delta_i}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(J\) | Clear juice to the evaporator | kg/s |
| \(B_0\) | Clear juice brix | - |
| \(B_s\) | Syrup brix | - |
| \(n\) | Number of effects | - |
| \(f\) | Dessin factor | - |
| \(T_0\) | Heating steam temperature (effect 1) | K |
| \(T_1\) | Vapour temperature leaving effect 1 | K |
| \(T_2\) | Vapour temperature leaving effect 2 | K |
| \(T_3\) | Vapour temperature leaving effect 3 | K |
| \(T_4\) | Vapour temperature leaving effect 4 | K |
| \(T_5\) | Vapour temperature leaving effect 5 | K |
| \(d_1\) | Boiling-point rise in effect 1 (brix and head) | K |
| \(d_2\) | Boiling-point rise in effect 2 (brix and head) | K |
| \(d_3\) | Boiling-point rise in effect 3 (brix and head) | K |
| \(d_4\) | Boiling-point rise in effect 4 (brix and head) | K |
| \(d_5\) | Boiling-point rise in effect 5 (brix and head) | K |
| \(P_1\) | Vapour bled from effect 1 | kg/s |
| \(P_2\) | Vapour bled from effect 2 | kg/s |
| \(P_3\) | Vapour bled from effect 3 | kg/s |
| \(P_4\) | Vapour bled from effect 4 | kg/s |
| \(E\) | Total evaporation | kg/s |
| \(x\) | Vapour to the condenser | kg/s |
| \(q_1\) | Evaporation of effect 1 (= heating steam, Rillieux) | kg/s |
| \(q_2\) | Evaporation of effect 2 | kg/s |
| \(q_3\) | Evaporation of effect 3 | kg/s |
| \(q_4\) | Evaporation of effect 4 | kg/s |
| \(q_5\) | Evaporation of effect 5 | kg/s |
| \(B_1\) | Brix leaving effect 1 | - |
| \(B_2\) | Brix leaving effect 2 | - |
| \(B_3\) | Brix leaving effect 3 | - |
| \(B_4\) | Brix leaving effect 4 | - |
| \(B_5\) | Brix leaving effect 5 | - |
| \(S_1\) | Heating surface of effect 1 | m² |
| \(S_2\) | Heating surface of effect 2 | m² |
| \(S_3\) | Heating surface of effect 3 | m² |
| \(S_4\) | Heating surface of effect 4 | m² |
| \(S_5\) | Heating surface of effect 5 | m² |
| \(S\) | Total heating surface | m² |
Method and standards
Hugot's multiple-effect method with Dessin's coefficient.
Where it is used
- Evaporator design and expansion.
- Planning vapour bleeding.
Common mistakes
- Bleeding more than the effects evaporate.
- Leaving out the hydrostatic rise in d.
Assumptions and limits
- Juice enters at its boiling point; add the first-vessel heating surface separately.
- Rillieux idealisation: 1 kg of steam or vapour evaporates 1 kg, so the steam to effect 1 equals q₁; flash, heat losses and changing latent heat are ignored.
- In the Dessin coefficient b_i is the mean of the brix entering and leaving the effect, in per cent.
- The boiling-point rises d_i are entered, not computed from brix and liquid head.
References
- Hugot
- Handbook of Cane Sugar Engineering
- 3rd ed. (Elsevier, 1986)
- ch. 32
- multiple-effect calculations
- eqns 32.20 and 32.31 and the example of pp. 588–591
Questions and answers
How is each effect's evaporation found?
The last effect sends x to the condenser; every effect also supplies the vapour bled from it and from the effects after it, so E = n x + Σ i Pᵢ.
What mean brix does Hugot use?
The average of the brix entering and leaving each effect.
Are the surfaces final?
They are design values at the chosen temperatures; Hugot then checks the minimum-total-surface distribution.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.