FireCADCalc

Evaporator Last-Body Vacuum and Syrup Temperature

Vacuum and absolute pressure of the last evaporator body for a vapour temperature (IF97), and the syrup temperature with its boiling-point elevation (Hugot ch. 32).

Sugar mill and cogenerationIAPWS-IF97 (water and steam)

Inputs

Examples: Hugot: 55 °CHill factory 60 °C

Hugot: about 55 °C, 64 cmHg vacuum, keeps the syrup near 60 °C for the pans.

Results

Below about 60 °C syrup can form false grain in the pans (Java practice); a higher vacuum also raises entrainment.

Absolute pressure19.946kPa
Vacuum (barometric minus absolute)525.45mmHg
Boiling-point elevation2.8767K
Syrup temperature62.877°C

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Hugot: 55 °C. The inputs, in the units selected above:

InputValue
Vapour temperature of the last body55.000 °C
Barometric pressure101.33 kPa
Syrup brix65.000 %

Applying the formula below gives:

ResultValue
Absolute pressure15.761 kPa
Vacuum (barometric minus absolute)641.78 mmHg
Boiling-point elevation3.1584 K
Syrup temperature58.158 °C

Open this example in the calculator and change any input.

Formula

\(p = p_{sat}(T_n), \quad h = p_a - p, \quad T_s = T_n + e\)

\(e = 0.025\,\frac{B(30 + B)}{103.6 - B}\left(1 - \frac{0.54\,h}{229 - h}\right)\quad (B\ \text{in brix},\ h\ \text{in cmHg},\ e\ \text{in}\ ^\circ C)\)

Variables

Symbol Meaning SI unit
\(T_n\) Vapour temperature of the last body K
\(p_a\) Barometric pressure Pa
\(B\) Syrup brix -
\(p\) Absolute pressure Pa
\(h\) Vacuum (barometric minus absolute) Pa
\(e\) Boiling-point elevation K
\(T_s\) Syrup temperature K

Method and standards

IF97 saturation with Hugot's boiling-point elevation.

Where it is used

  • Setting evaporator vacuum.
  • Condenser duty.

Common mistakes

  • Quoting vacuum without the barometer.
  • Ignoring the syrup's elevation.

Assumptions and limits

  • Pure sucrose elevation by Hugot's formula; in it the vacuum is in cmHg (1 cmHg = 1333.224 Pa) against the local barometric pressure.
  • The vacuum is a pressure difference, shown in mmHg; the absolute pressure is the figure to compare between sites.
  • A note appears when the syrup leaves below about 60 °C.

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 32
  • maximum vacuum and boiling-point elevation
  • pp. 494–497 and 610
  • Saturation pressure from IAPWS-IF97

Questions and answers

Why not a deeper vacuum?

It widens the temperature range but cools the syrup below 60 °C and raises entrainment.

What sets the vacuum?

The condenser water temperature and quantity, and the air pump.

Vacuum or absolute pressure?

Vacuum is barometric minus absolute; quote absolute pressure when the altitude differs.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.