Worked example
Example: Pan condenser 16 kPa. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Vapour to the condenser | 20.000 t/h |
| Condenser pressure (absolute) | 16.000 kPa |
| Injection water in | 32.000 °C |
| Tail water out | 47.000 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Saturation temperature at condenser pressure | 55.314 °C |
| Injection water | 766.98 t/h |
| Water per kg of vapour | 38.349 |
Open this example in the calculator and change any input.
Formula
\(\frac{\dot m_w}{\dot m_v} = \frac{h_g(p_c) - h(T_{out})}{h(T_{out}) - h(T_{in})}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_v\) | Vapour to the condenser | kg/s |
| \(p_c\) | Condenser pressure (absolute) | Pa |
| \(T_{in}\) | Injection water in | K |
| \(T_{out}\) | Tail water out | K |
| \(T_s\) | Saturation temperature at condenser pressure | K |
| \(\dot m_w\) | Injection water | kg/s |
| \(\dot m_w/\dot m_v\) | Water per kg of vapour | - |
Method and standards
Energy balance.
Where it is used
- Pan and evaporator condensers.
- Spray pond and cooling tower sizing.
Common mistakes
- Ignoring the vapour superheat from BPE.
Assumptions and limits
- Saturated vapour; no air load.
- The tail water must stay below the vapour saturation temperature; an approach under about 2 K is flagged as unrealistic.
References
- Energy balance with IAPWS-IF97 enthalpies (saturated vapour, liquid water at 1 atm)
Questions and answers
Why some 30–60 kg of water per kg of vapour?
Each kg of vapour gives about 2400 kJ, while the water warms only 10–20 K; at a 15 K rise it is close to 38 kg.
What limits the outlet temperature?
The vapour saturation temperature at the vacuum needed.
Where does the water go?
To a spray pond or cooling tower and back.