Worked example
Example: 11 t/h vapour. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Vapour to condense | 11.000 t/h |
| Section per t/h of vapour (m² per t/h) | 0.15000 m² |
| Injection water | 550.00 m³/h |
| Water velocity in the supply pipe | 2.0000 m/s |
| Hole diameter | 15.000 mm |
Applying the formula below gives:
| Result | Value |
|---|---|
| Condenser section | 1.6500 m² |
| Condenser diameter | 1.4494 m |
| Water pipe section | 0.076389 m² |
| Water pipe diameter | 311.87 mm |
| Total hole area (3 a_p) | 0.22917 m² |
| Number of holes | 1,297.0 |
Open this example in the calculator and change any input.
Formula
\(S = \sigma Q, \quad D = \sqrt{4S/\pi}, \quad a_p = \frac{Q_w}{V_w}, \quad a_h = 3a_p, \quad n = \frac{a_h}{\pi d_h^2/4}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q\) | Vapour to condense | kg/s |
| \(\sigma\) | Section per t/h of vapour (m² per t/h) | m² |
| \(Q_w\) | Injection water | m³/s |
| \(V_w\) | Water velocity in the supply pipe | m/s |
| \(d_h\) | Hole diameter | m |
| \(S\) | Condenser section | m² |
| \(D\) | Condenser diameter | m |
| \(a_p\) | Water pipe section | m² |
| \(d_p\) | Water pipe diameter | m |
| \(a_h\) | Total hole area (3 a_p) | m² |
| \(n\) | Number of holes | - |
Method and standards
Hugot's proportions.
Where it is used
- Designing rain condensers.
- Retrofitting condensers.
Common mistakes
- Too few holes: the tray overflows.
- Too short a fall.
Assumptions and limits
- Hugot's proportions from practice.
- σ is in m² per t/h of vapour and is shown in m² in every unit system.
- The injection water is not checked against the vapour load, and the fall height and approach are not computed.
References
- Hugot
- Handbook of Cane Sugar Engineering
- 3rd ed. (Elsevier, 1986)
- ch. 40
- rain-type condensers
- pp. 893–895
Questions and answers
How does a rain condenser work?
Water falls as rain from a perforated tray through the rising vapour; no nozzles are needed.
Why three times the pipe area for holes?
The holes discharge under little head; ample area keeps the tray from flooding.
Section per t/h?
Hugot: 0.1–0.2 m² per tonne of vapour per hour.