Worked example
Example: 770 mmHg, 3 cmHg abs, 1 m/s. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Barometric pressure | 770.00 mmHg |
| Condenser pressure (absolute) | 3.0000 cmHg |
| Water temperature in the column | 45.000 °C |
| Vapour condensed | 11,000 kg/h |
| Water per kg vapour | 50.000 - |
| Velocity in the column | 1.0000 m/s |
| Loss coefficient of the column | 1.0000 - |
| Margin | 0.50000 m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Water density | 990.22 kg/m³ |
| Static column for the vacuum | 10.160 m |
| Velocity head with losses | 0.10197 m |
| Column height | 10.762 m |
| Column diameter | 447.63 mm |
Open this example in the calculator and change any input.
Formula
\(H_0 = \frac{p_a - p}{\rho_w g}, \quad h = (1 + \alpha)\frac{V^2}{2g}, \quad H = H_0 + h + s, \quad D = \sqrt{\frac{4Q(W + 1)}{\rho_w\pi V}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(p_a\) | Barometric pressure | Pa |
| \(p\) | Condenser pressure (absolute) | Pa |
| \(t_w\) | Water temperature in the column | K |
| \(Q\) | Vapour condensed | kg/s |
| \(W\) | Water per kg vapour | - |
| \(V\) | Velocity in the column | m/s |
| \(\alpha\) | Loss coefficient of the column | - |
| \(s\) | Margin | m |
| \(\rho_w\) | Water density | kg/m³ |
| \(H_0\) | Static column for the vacuum | m |
| \(h\) | Velocity head with losses | m |
| \(H\) | Column height | m |
| \(D\) | Column diameter | m |
Method and standards
Hugot's column balance.
Where it is used
- Condenser installation.
- Checking flooding of condensers.
Common mistakes
- Using cold-water density.
- Leaving out the condensate in the flow.
Assumptions and limits
- Steady flow; sealed well.
- The water must be below its boiling point at the condenser pressure; a note appears if not.
References
- Hugot
- Handbook of Cane Sugar Engineering
- 3rd ed. (Elsevier, 1986)
- ch. 40
- barometric column
- eqns 40.19–40.23
- pp. 881–883
- Water density from IAPWS-IF97
Questions and answers
Why add the velocity head?
Water must flow down the column, so it needs head beyond the static balance, plus losses at entry and along the pipe.
Why warm-water density?
The column holds the warm discharge water, lighter than cold water, so it must be a little taller.
How big a margin?
Hugot: about 0.5 m for surges and barometer changes.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.