FireCADCalc

Sugar Factory Water Requirements (Hugot)

Water a raw sugar factory needs per hour by use from the crush (Hugot, p. 891) and the condenser cold water from vapour and temperatures (40.27–40.30).

Sugar mill and cogeneration

Inputs

Examples: 100 TCH, 54 and 21 °C250 TCH

Hugot: 30Q for central condensers, 60Q for individual ones (×1.5 and ×3 of the theoretical 20Q).

Results

Hugot's process coefficients per t cane/h: boilers 0.05, bearings 0.20, filters 0.04, A cooling 0.20, B 0.09, C 0.06, movement water 0.02, sugar coolers 0.30, centrifugals 0.01 m³/h (0.97 in all), plus imbibition.

Process water (bearings, filters, cooling, centrifugals, boilers)97.000m³/h
Imbibition water30.000m³/h
Water per kg vapour 650/(t_v − t₁)19.697
Condenser cold water886.36m³/h
Condenser water per tonne cane8.8636m³/t

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 100 TCH, 54 and 21 °C. The inputs, in the units selected above:

InputValue
Crushing rate100.00 t/h
Imbibition water per tonne cane0.30000 m³/t
Vapour to the condensers per tonne cane300.00 kg/t
Vapour temperature54.000 °C
Cold water temperature21.000 °C
Margin on condenser water1.5000 -

Applying the formula below gives:

ResultValue
Process water (bearings, filters, cooling, centrifugals, boilers)97.000 m³/h
Imbibition water30.000 m³/h
Water per kg vapour 650/(t_v − t₁)19.697
Condenser cold water886.36 m³/h
Condenser water per tonne cane8.8636 m³/t

Open this example in the calculator and change any input.

Formula

\(\dot V_p = 0.97A, \quad W = \frac{650}{t_v - t_1}, \quad \dot V_c = k\,W\,Q\,A\)

Variables

Symbol Meaning SI unit
\(A\) Crushing rate kg/s
\(w\) Imbibition water per tonne cane m³/kg
\(Q\) Vapour to the condensers per tonne cane kg/kg
\(t_v\) Vapour temperature K
\(t_1\) Cold water temperature K
\(k\) Margin on condenser water -
\(\dot V_p\) Process water (bearings, filters, cooling, centrifugals, boilers) m³/s
\(\dot V_i\) Imbibition water m³/s
\(W\) Water per kg vapour 650/(t_v − t₁) -
\(\dot V_c\) Condenser cold water m³/s
\(\dot V_c/A\) Condenser water per tonne cane m³/kg

Method and standards

Hugot's coefficients and condenser balance.

Where it is used

  • Water supply planning.
  • ZLD and recycling studies.

Common mistakes

  • Counting imbibition twice.
  • Using a single condenser margin for all designs.

Assumptions and limits

  • Raw sugar factory with crystallisers cooled by water.
  • W = 650/(t_v − t₁) assumes the water leaves at the vapour temperature (no approach); the margin k must cover the real approach.
  • With no crush the water per tonne is not shown.

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 40
  • factory water requirements
  • eqns 40.27–40.30 and p. 891

Questions and answers

Why so much condenser water?

About 20 kg of water per kg of vapour at a 33 °C range; 300 kg of vapour per tonne cane needs about 6 m³ of water.

Where does process water come from?

Mostly from vapour condensates; fresh water is needed mainly for make-up and the condensers.

Why margins?

Hugot: allow 30Q for central and 60Q for individual condensers to cope with peaks and warm water.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.