Worked example
Example: 16 kPa at sea level. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Condenser pressure (absolute) | 16.000 kPa |
| Atmospheric pressure | 101.33 kPa |
| Tail water density | 990.00 kg/m³ |
| Safety margin | 1.0000 m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Column balancing the vacuum | 8.7886 m |
| Leg height with margin | 9.7886 m |
Open this example in the calculator and change any input.
Formula
\(H = \frac{p_a - p_c}{\rho g} + \Delta h\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(p_c\) | Condenser pressure (absolute) | Pa |
| \(p_a\) | Atmospheric pressure | Pa |
| \(\rho\) | Tail water density | kg/m³ |
| \(\Delta h\) | Safety margin | m |
| \(h_0\) | Column balancing the vacuum | m |
| \(H\) | Leg height with margin | m |
Method and standards
Hydrostatics.
Where it is used
- Condenser installation.
- Retrofit checks.
Common mistakes
- Gauge vacuum entered as absolute pressure.
Assumptions and limits
- Static column only: no velocity head or friction. The margin must cover them; the Hugot barometric column calculator adds them explicitly, so it gives a taller column for the same case.
References
- Hydrostatics h = (p_a − p_c)/(ρ g)
Questions and answers
Why about 10 m?
A full vacuum balances about 10.3 m of water at sea level.
Why a margin?
Velocity head, friction and surges must not let water rise into the condenser.
At altitude?
Lower atmospheric pressure shortens the column needed.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.