Worked example
Example: Hugot pan example: 25 200 kg/h, 6 g/kg, 30 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Vapour condensed | 25,200 kg/h |
| Air per kg vapour | 6.0000 g/kg |
| Condenser pressure (absolute) | 13.337 kPa |
| Air temperature at the air outlet | 30.000 °C |
| Volumetric efficiency of the pump | 70.000 % |
| Ejector steam per kg of dry air | 8.5000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Dry air | 151.20 kg/h |
| Vapour pressure at t_a | 4.2467 kPa |
| Partial pressure of air | 9.0904 kPa |
| Specific volume of the air | 9.5724 m³/kg |
| Air volume at the outlet | 24.123 m³/min |
| Pump displacement | 34.461 m³/min |
| Steam for a steam-jet ejector | 1,285.2 kg/h |
Open this example in the calculator and change any input.
Formula
\(\dot m_a = aG, \quad p_a = p - p_{sat}(t_a), \quad v_a = \frac{R_a T_a}{p_a}, \quad \dot V_a = \dot m_a v_a, \quad \dot V_d = \frac{\dot V_a}{\eta_v}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(G\) | Vapour condensed | kg/s |
| \(a\) | Air per kg vapour | kg/kg |
| \(p\) | Condenser pressure (absolute) | Pa |
| \(t_a\) | Air temperature at the air outlet | K |
| \(\eta_v\) | Volumetric efficiency of the pump | - |
| \(s_e\) | Ejector steam per kg of dry air | - |
| \(\dot m_a\) | Dry air | kg/s |
| \(p_v\) | Vapour pressure at t_a | Pa |
| \(p_a\) | Partial pressure of air | Pa |
| \(v_a\) | Specific volume of the air | m³/kg |
| \(\dot V_a\) | Air volume at the outlet | m³/s |
| \(\dot V_d\) | Pump displacement | m³/s |
| \(\dot m_s\) | Steam for a steam-jet ejector | kg/s |
Method and standards
Dalton's and Mariotte's laws as used by Hugot.
Where it is used
- Sizing vacuum pumps and ejectors.
- Diagnosing poor vacuum.
Common mistakes
- Using condenser pressure as air pressure.
- Ignoring the air from leaks.
Assumptions and limits
- Saturated air at t_a. As t_a approaches the saturation temperature at p the air partial pressure tends to zero and the volume grows without limit; a note warns when the air is below a quarter of p.
References
- Hugot
- Handbook of Cane Sugar Engineering
- 3rd ed. (Elsevier, 1986)
- ch. 40
- air extraction (Tables 40.9–40.16, Mariotte's law, example p. 878) and ejectors
- pp. 867–880 and 901–903
- Gas constant of dry air from CODATA R and the air composition
Questions and answers
Why so much volume for so little air?
At 10 kPa the air is a tenth of atmospheric density, and the vapour mixed with it lowers its partial pressure further.
Why cool the air before the pump?
Colder air carries less vapour and has a higher partial pressure, so the pump handles less volume.
Liquid-ring or ejector?
Liquid-ring pumps use about an eighth of the energy of steam ejectors (Hugot).
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.