Worked example
Example: Hugot: 100 t/h, 30-65-85-103 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Juice flow | 100.00 t/h |
| Juice specific heat | 3.7681 kJ/(kg·K) |
| Heater efficiency | 95.000 % |
| Juice in | 30.000 °C |
| After stage 1 | 65.000 °C |
| After stage 2 | 85.000 °C |
| After stage 3 | 103.00 °C |
| Vapour temperature, stage 1 | 85.000 °C |
| Vapour temperature, stage 2 | 100.00 °C |
| Vapour temperature, stage 3 | 111.00 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Vapour for stage 1 | 6,048.0 kg/h |
| Vapour for stage 2 | 3,515.6 kg/h |
| Vapour for stage 3 | 3,205.9 kg/h |
| Total vapour | 12,770 kg/h |
| Smallest margin vapour to juice outlet | 8.0000 K |
Open this example in the calculator and change any input.
Formula
\(P_i = \frac{\dot m_j c (t_i - t_{i-1})}{h_{fg}(T_i)\,\eta}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_j\) | Juice flow | kg/s |
| \(c\) | Juice specific heat | J/(kg·K) |
| \(\eta\) | Heater efficiency | - |
| \(t_0\) | Juice in | K |
| \(t_1\) | After stage 1 | K |
| \(t_2\) | After stage 2 | K |
| \(t_3\) | After stage 3 | K |
| \(T_1\) | Vapour temperature, stage 1 | K |
| \(T_2\) | Vapour temperature, stage 2 | K |
| \(T_3\) | Vapour temperature, stage 3 | K |
| \(P_1\) | Vapour for stage 1 | kg/s |
| \(P_2\) | Vapour for stage 2 | kg/s |
| \(P_3\) | Vapour for stage 3 | kg/s |
| \(\Sigma P\) | Total vapour | kg/s |
| \(T_i - t_i\) | Smallest margin vapour to juice outlet | K |
Method and standards
Heat balance per heater with IF97 latent heat.
Where it is used
- Planning heater batteries.
- Evaporator bleed calculations.
Common mistakes
- Using exhaust latent heat for all stages.
- Too small a margin for the vapour.
Assumptions and limits
- Condensate leaves saturated.
- A note appears when the smallest vapour-to-juice margin is below 5 K.
References
- Hugot
- Handbook of Cane Sugar Engineering
- 3rd ed. (Elsevier, 1986)
- ch. 30 (Table 30.1 margins) and ch. 32 example
- p. 589
- Latent heat from IAPWS-IF97
Questions and answers
Why heat with vapour rather than exhaust?
Each kilogram of vapour bled from effect n saves about n/N kg of exhaust in an N-effect evaporator (Rillieux).
Which effect for which stage?
The coldest vapour that still leaves the margin: last effects for the first stage, first effect or exhaust for the final stage.
Hugot's example?
100 t/h juice heated 30–65–85–103 °C by vapours at 85, 100 and 111 °C takes about 6 050, 3 515 and 3 204 kg/h by Hugot's tables; with IAPWS-IF97 latent heats this page gives 6 048, 3 516 and 3 206 kg/h.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.