FireCADCalc

Juice Heating by Vapour Bleeding: Three Stages

Vapour bled from evaporator effects to heat juice in three stages, from juice flow, specific heat, stage temperatures and IF97 latent heats (Hugot p. 589).

Sugar mill and cogenerationIAPWS-IF97 (water and steam)Boiler

Inputs

Examples: Hugot: 100 t/h, 30-65-85-103 °CHotter last stage

Results

Hugot's margins between vapour and juice outlet: 5–8 °C on exhaust, 10–12 °C on first-effect vapour, 15–20 °C on later vapours.

Vapour for stage 19,242.9kg/h
Vapour for stage 25,390.6kg/h
Vapour for stage 34,116.7kg/h
Total vapour18,750kg/h
Smallest margin vapour to juice outlet10.000K

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Hugot: 100 t/h, 30-65-85-103 °C. The inputs, in the units selected above:

InputValue
Juice flow100.00 t/h
Juice specific heat3.7681 kJ/(kg·K)
Heater efficiency95.000 %
Juice in30.000 °C
After stage 165.000 °C
After stage 285.000 °C
After stage 3103.00 °C
Vapour temperature, stage 185.000 °C
Vapour temperature, stage 2100.00 °C
Vapour temperature, stage 3111.00 °C

Applying the formula below gives:

ResultValue
Vapour for stage 16,048.0 kg/h
Vapour for stage 23,515.6 kg/h
Vapour for stage 33,205.9 kg/h
Total vapour12,770 kg/h
Smallest margin vapour to juice outlet8.0000 K

Open this example in the calculator and change any input.

Formula

\(P_i = \frac{\dot m_j c (t_i - t_{i-1})}{h_{fg}(T_i)\,\eta}\)

Variables

Symbol Meaning SI unit
\(\dot m_j\) Juice flow kg/s
\(c\) Juice specific heat J/(kg·K)
\(\eta\) Heater efficiency -
\(t_0\) Juice in K
\(t_1\) After stage 1 K
\(t_2\) After stage 2 K
\(t_3\) After stage 3 K
\(T_1\) Vapour temperature, stage 1 K
\(T_2\) Vapour temperature, stage 2 K
\(T_3\) Vapour temperature, stage 3 K
\(P_1\) Vapour for stage 1 kg/s
\(P_2\) Vapour for stage 2 kg/s
\(P_3\) Vapour for stage 3 kg/s
\(\Sigma P\) Total vapour kg/s
\(T_i - t_i\) Smallest margin vapour to juice outlet K

Method and standards

Heat balance per heater with IF97 latent heat.

Where it is used

  • Planning heater batteries.
  • Evaporator bleed calculations.

Common mistakes

  • Using exhaust latent heat for all stages.
  • Too small a margin for the vapour.

Assumptions and limits

  • Condensate leaves saturated.
  • A note appears when the smallest vapour-to-juice margin is below 5 K.

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 30 (Table 30.1 margins) and ch. 32 example
  • p. 589
  • Latent heat from IAPWS-IF97

Questions and answers

Why heat with vapour rather than exhaust?

Each kilogram of vapour bled from effect n saves about n/N kg of exhaust in an N-effect evaporator (Rillieux).

Which effect for which stage?

The coldest vapour that still leaves the margin: last effects for the first stage, first effect or exhaust for the final stage.

Hugot's example?

100 t/h juice heated 30–65–85–103 °C by vapours at 85, 100 and 111 °C takes about 6 050, 3 515 and 3 204 kg/h by Hugot's tables; with IAPWS-IF97 latent heats this page gives 6 048, 3 516 and 3 206 kg/h.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.