Roots (Twin-Lobe) Blower Power and Discharge Temperature

Gas power, shaft power and discharge temperature of a rotary-lobe (Roots) blower, which has no internal compression, compared with ideal isentropic compression.

Inputs

Examples: Illustrative 1000 m3/h air blower, 0.6 barAeration blower 0.5 barVacuum duty

Accepted: 0.36 to 180,000 m³/h
Accepted: 0.1 to 5 bar
Accepted: 0.1 to 10 bar
Accepted: -50 to 100 °C
Accepted: 50 to 100 %
Accepted: 1.05 to 1.67
Accepted: 0.05 to 5 kJ/(kg·K)

Results

A Roots blower carries pockets of gas at inlet pressure to the outlet, where discharge gas flows back and compresses them suddenly. The work per cycle is therefore the inlet volume times the full pressure rise, V₁(p₂ − p₁), more than isentropic compression needs; the gap grows with the pressure ratio, which is why lobe blowers are used below about 1 bar rise. All the gas work turns into heat in the gas, giving the discharge temperature rise. Slip back through the clearances reduces the delivered flow; enter the delivered inlet flow.

Gas power (inlet volume × pressure rise)7.1285kW
Shaft power7.9205kW
Ideal isentropic gas power5.4349kW
Isentropic efficiency of the lobe compression76.242%
Discharge temperature112.44°C
Mass flow292.11kg/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 1000 m3/h air blower, 0.6 bar. The inputs, in the units selected above:

InputValue
Inlet volume flow1,000.0 m³/h
Inlet pressure (absolute)1.0132 bar
Discharge pressure (absolute)1.6133 bar
Inlet temperature30.000 °C
Mechanical efficiency (gears, bearings, seals)92.000 %
Ratio of specific heats1.4000 -
Gas constant0.28705 kJ/(kg·K)

Applying the formula below gives:

ResultValue
Gas power (inlet volume × pressure rise)16.667 kW
Shaft power18.116 kW
Ideal isentropic gas power14.000 kW
Isentropic efficiency of the lobe compression83.999 %
Discharge temperature81.289 °C
Mass flow1,164.4 kg/h

Open this example in the calculator and change any input.

Formula

\(P_g = \dot V_1 (p_2 - p_1), \quad P_{is} = \dot m c_p T_1\left[\left(\frac{p_2}{p_1}\right)^{(\kappa-1)/\kappa} - 1\right], \quad T_2 = T_1 + \frac{P_g}{\dot m c_p}\)

Variables

Symbol Meaning SI unit
\(\dot V_1\) Inlet volume flow m³/s
\(p_1\) Inlet pressure (absolute) Pa
\(p_2\) Discharge pressure (absolute) Pa
\(T_1\) Inlet temperature K
\(\eta_m\) Mechanical efficiency (gears, bearings, seals) -
\(\kappa\) Ratio of specific heats -
\(R\) Gas constant J/(kg·K)
\(P_g\) Gas power (inlet volume × pressure rise) W
\(P_s\) Shaft power W
\(P_{is}\) Ideal isentropic gas power W
\(\eta_{is}\) Isentropic efficiency of the lobe compression -
\(T_2\) Discharge temperature K
\(\dot m\) Mass flow kg/s

Method and standards

Lobe blower.

Where it is used

  • Aeration, pneumatic conveying and vacuum duties.
  • Comparing lobe blowers with screw and turbo blowers.

Common mistakes

  • Using the isentropic formula for a lobe blower.
  • Entering the swept volume instead of the delivered flow.

Assumptions and limits

  • Ideal gas; no heat loss; delivered inlet flow given.

References

  • Positive-displacement compression without internal compression: W = V₁(p₂ − p₁)

Questions and answers

Why is a Roots blower less efficient at higher pressure?

It has no internal compression: the gas is compressed by backflow at the outlet, so its work is V₁Δp, always more than isentropic.

What discharge temperature should I expect?

About 50 K above inlet at 0.6 bar rise from atmosphere, rising roughly in proportion to the pressure rise.

What do the defaults represent?

An illustrative 1,000 m³/h air blower lifting 0.6 bar from atmosphere at 30 °C.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.