Reciprocating Compressor Gas Rod Load

Gas rod loads in compression and tension of a double-acting reciprocating compressor cylinder from bore, piston rod diameter and suction and discharge pressures.

Thermal power plantProcess steam and utilities

Inputs

Examples: Illustrative 300 mm bore, 10 to 30 barHigh ratio 5 to 30 barHigh-pressure stage 100 to 200 bar

Accepted: 0.02 to 2 m
Accepted: 0.005 to 0.5 m
Accepted: 0.01 to 50 MPa
Accepted: 0.01 to 50 MPa
Accepted: 0 to 1,000 kPa

Results

Gas loads at the dead centres: compression = p_dA_h − p_sA_c − p_aA_rod; tension = p_dA_c + p_aA_rod − p_sA_h. Makers limit both; the load must also reverse each revolution to lubricate the crosshead pin. Inertia loads are added in a full rod-load analysis.

Head-end piston area490.87cm²
Crank-end piston area457.69cm²
Rod load in compression124.04kN
Rod load in tension113.10kN
Rod load reverses (1 yes, 0 no)1.0000

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 300 mm bore, 10 to 30 bar. The inputs, in the units selected above:

InputValue
Cylinder bore0.30000 m
Piston rod diameter0.070000 m
Suction pressure (absolute)1.0000 MPa
Discharge pressure (absolute)3.0000 MPa
Pressure acting on the rod end outside the packing (absolute)101.33 kPa

Applying the formula below gives:

ResultValue
Head-end piston area706.86 cm²
Crank-end piston area668.37 cm²
Rod load in compression144.83 kN
Rod load in tension130.22 kN
Rod load reverses (1 yes, 0 no)1.0000

Open this example in the calculator and change any input.

Formula

\(F_c = p_dA_h - p_sA_c - p_aA_r, \quad F_t = p_dA_c + p_aA_r - p_sA_h\)

Variables

Symbol Meaning SI unit
\(D\) Cylinder bore m
\(d\) Piston rod diameter m
\(p_s\) Suction pressure (absolute) Pa
\(p_d\) Discharge pressure (absolute) Pa
\(p_a\) Pressure acting on the rod end outside the packing (absolute) Pa
\(A_h\) Head-end piston area m²
\(A_c\) Crank-end piston area m²
\(F_c\) Rod load in compression N
\(F_t\) Rod load in tension N
\(\text{reversal}\) Rod load reverses (1 yes, 0 no) -

Method and standards

Rod load.

Where it is used

  • Compressor rerates and pressure changes.
  • Checking operating envelopes.

Common mistakes

  • Using gauge pressures with the atmospheric term.
  • Ignoring inertia loads at high speed.

Assumptions and limits

  • Static gas loads at dead centres; no valve losses.

References

  • Gas rod load of a double-acting cylinder

Questions and answers

Why must rod load reverse?

The crosshead pin is lubricated only when the load changes direction; without reversal the oil film fails and the pin seizes.

What raises rod load?

Higher discharge pressure or lower suction pressure across the same piston, as when a stage runs at a high pressure ratio.

What do the defaults represent?

An illustrative 300 mm bore with a 70 mm rod, suction 10 bar and discharge 30 bar absolute.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Brown, Compressors: Selection and Sizing, 3rd ed. (Gulf Professional, 2005)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.