FireCADCalc

Compressor Load/Unload Cycle Rate and Minimum Receiver

Load and unload times, cycles per hour and load share of a compressor with a receiver at a demand, and the receiver volume that limits the cycle rate.

Inputs

Examples: Illustrative 10 m3/min on 2 m3Large receiver, light demandWide band, half demand

Accepted: 0.01 to 1,000 m³
Accepted: 0.06 to 6,000 m³/min
Accepted: 0.006 to 6,000 m³/min
Accepted: 0.1 to 5 bar
Accepted: 0.5 to 1.1 bar
Accepted: 1 to 200

Results

While loaded the compressor fills the receiver at the surplus Q_c − Q_d; unloaded, the demand draws it down. Each phase takes V·Δp/p_a divided by that flow (isothermal). Cycling is fastest when demand is half the delivery, giving a cycle of 4VΔp/(p_aQ_c); a receiver of at least 3600·p_a·Q_c/(4Δp·N_max) keeps cycles below N_max per hour at any demand. Frequent cycling wastes unload power and wears valves and motors; a wider band or a bigger receiver slows it.

Load time88.823s
Unload time88.823s
Cycles per hour20.265
Load share50.000%
Volume for the maximum cycle rate at worst demand4.0530m³

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 10 m3/min on 2 m3. The inputs, in the units selected above:

InputValue
Receiver and system volume2.0000 m³
Compressor free air delivery10.000 m³/min
Air demand (free air)6.0000 m³/min
Pressure band (cut-in to cut-out)1.0000 bar
Atmospheric pressure1.0132 bar
Maximum cycles per hour allowed30.000 -

Applying the formula below gives:

ResultValue
Load time29.608 s
Unload time19.738 s
Cycles per hour72.954
Load share60.000 %
Volume for the maximum cycle rate at worst demand5.0663 m³

Open this example in the calculator and change any input.

Formula

\(t_l = \frac{V\Delta p}{p_a(Q_c - Q_d)}, \quad t_u = \frac{V\Delta p}{p_aQ_d}, \quad V_{min} = \frac{p_aQ_c}{4\Delta p\,N_{max}}\)

Variables

Symbol Meaning SI unit
\(V\) Receiver and system volume m³
\(Q_c\) Compressor free air delivery m³/s
\(Q_d\) Air demand (free air) m³/s
\(\Delta p\) Pressure band (cut-in to cut-out) Pa
\(p_a\) Atmospheric pressure Pa
\(N_{max}\) Maximum cycles per hour allowed -
\(t_l\) Load time s
\(t_u\) Unload time s
\(N\) Cycles per hour -
\(Q_d/Q_c\) Load share -
\(V_{min}\) Volume for the maximum cycle rate at worst demand m³

Method and standards

Compressor cycling.

Where it is used

  • Compressed air system design.
  • Energy audits of load/unload compressors.

Common mistakes

  • Forgetting pipework volume.
  • Using gauge for atmospheric pressure.

Assumptions and limits

  • Isothermal filling; steady demand.

References

  • Isothermal receiver filling and emptying

Questions and answers

How often does a 10 m³/min compressor cycle on a 2 m³ receiver at 6 m³/min demand with a 1 bar band?

About 73 cycles an hour (30 s loaded, 20 s unloaded).

What receiver keeps it below 30 cycles an hour?

About 5.1 m³ including pipework.

What do the defaults represent?

An illustrative 10 m³/min compressor with 2 m³ of receiver and pipework, 6 m³/min demand, 1 bar band, at most 30 cycles an hour.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators