FireCADCalc

Compressed Air Leakage by Pressure Decay Test

Leakage of a compressed air system as free air delivery from the pressure drop over time with compressors off, the share of compressor output and the yearly cost.

Thermal power plantProcess steam and utilities

Inputs

Examples: Illustrative 10 m3, 8 to 6.5 bar in 2 min, 30 m3/min compressorLarge plant 40 m3, 7.5 to 6.5 bar in 1 minTight system 5 m3, 8 to 7.5 bar in 5 min

Accepted: 0.01 to 10,000 m³
Accepted: 120 to 5,000 kPa
Accepted: 110 to 5,000 kPa
Accepted: 1 to 100,000 s
Accepted: 50 to 110 kPa
Accepted: 0.06 to 6,000 m³/min
Accepted: 3 to 15
Accepted: 0 to 8,760 h
Accepted: 0 to 1

Results

Isothermal pressure decay: Q_L = V(p₁ − p₂)/(p₀t). Leaks fall as pressure drops, so start near working pressure and keep the drop moderate. Typical plants lose 20–30 % of compressor output to leaks; under 10 % is good practice.

Leakage as free air0.49346m³/min
Leakage share of compressor output4.9346%
Power wasted3.4542kW
Energy wasted per year13.817MWh
Cost per year1,105.4

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 10 m3, 8 to 6.5 bar in 2 min, 30 m3/min compressor. The inputs, in the units selected above:

InputValue
System volume (receivers and pipework)10.000 m³
Start pressure (absolute)800.00 kPa
End pressure (absolute)650.00 kPa
Time for the drop120.00 s
Atmospheric pressure101.33 kPa
Compressor capacity (FAD)30.000 m³/min
Specific power (kW per m³/min of FAD)6.5000 -
Pressurised hours per year6,000.0 h
Electricity price (per kWh)0.10000 -

Applying the formula below gives:

ResultValue
Leakage as free air7.4019 m³/min
Leakage share of compressor output24.673 %
Power wasted48.113 kW
Energy wasted per year288.68 MWh
Cost per year28,868

Open this example in the calculator and change any input.

Formula

\(Q_L = \frac{V(p_1 - p_2)}{p_0t}, \quad P_L = SP\cdot Q_L\)

Variables

Symbol Meaning SI unit
\(V\) System volume (receivers and pipework) m³
\(p_1\) Start pressure (absolute) Pa
\(p_2\) End pressure (absolute) Pa
\(t\) Time for the drop s
\(p_0\) Atmospheric pressure Pa
\(Q_c\) Compressor capacity (FAD) m³/s
\(SP\) Specific power (kW per m³/min of FAD) -
\(h\) Pressurised hours per year s
\(c_e\) Electricity price (per kWh) -
\(Q_L\) Leakage as free air m³/s
\(Q_L/Q_c\) Leakage share of compressor output -
\(P_L\) Power wasted W
\(E\) Energy wasted per year J
\(C\) Cost per year -

Method and standards

Leak test.

Where it is used

  • Compressed air energy audits.
  • Leak-repair programmes.

Common mistakes

  • Forgetting the pipework volume.
  • Testing with users still drawing air.

Assumptions and limits

  • Isothermal; constant leak orifices over the test.

References

  • Pressure-decay leak test

Questions and answers

How do I run a pressure-decay test?

With all users off and compressors stopped, time how long the system takes to fall from working pressure to a lower pressure; the volume must be known.

Why measure leaks?

Leaks run 24 hours a day; a plant losing 25 % of a 100 kW compressor's air wastes about 200 MWh a year.

What do the defaults represent?

An illustrative 10 m³ system falling from 8 to 6.5 bar absolute in 2 minutes, a 30 m³/min compressor at 6.5 kW per m³/min, 6,000 hours a year at 0.10 per kWh.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Brown, Compressors: Selection and Sizing, 3rd ed. (Gulf Professional, 2005)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.