Worked example
Example: Illustrative 10 m3, 8 to 6.5 bar in 2 min, 30 m3/min compressor. The inputs, in the units selected above:
| Input | Value |
|---|---|
| System volume (receivers and pipework) | 10.000 m³ |
| Start pressure (absolute) | 800.00 kPa |
| End pressure (absolute) | 650.00 kPa |
| Time for the drop | 120.00 s |
| Atmospheric pressure | 101.33 kPa |
| Compressor capacity (FAD) | 30.000 m³/min |
| Specific power (kW per m³/min of FAD) | 6.5000 - |
| Pressurised hours per year | 6,000.0 h |
| Electricity price (per kWh) | 0.10000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Leakage as free air | 7.4019 m³/min |
| Leakage share of compressor output | 24.673 % |
| Power wasted | 48.113 kW |
| Energy wasted per year | 288.68 MWh |
| Cost per year | 28,868 |
Open this example in the calculator and change any input.
Formula
\(Q_L = \frac{V(p_1 - p_2)}{p_0t}, \quad P_L = SP\cdot Q_L\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(V\) | System volume (receivers and pipework) | m³ |
| \(p_1\) | Start pressure (absolute) | Pa |
| \(p_2\) | End pressure (absolute) | Pa |
| \(t\) | Time for the drop | s |
| \(p_0\) | Atmospheric pressure | Pa |
| \(Q_c\) | Compressor capacity (FAD) | m³/s |
| \(SP\) | Specific power (kW per m³/min of FAD) | - |
| \(h\) | Pressurised hours per year | s |
| \(c_e\) | Electricity price (per kWh) | - |
| \(Q_L\) | Leakage as free air | m³/s |
| \(Q_L/Q_c\) | Leakage share of compressor output | - |
| \(P_L\) | Power wasted | W |
| \(E\) | Energy wasted per year | J |
| \(C\) | Cost per year | - |
Method and standards
Leak test.
Where it is used
- Compressed air energy audits.
- Leak-repair programmes.
Common mistakes
- Forgetting the pipework volume.
- Testing with users still drawing air.
Assumptions and limits
- Isothermal; constant leak orifices over the test.
References
- Pressure-decay leak test
Questions and answers
How do I run a pressure-decay test?
With all users off and compressors stopped, time how long the system takes to fall from working pressure to a lower pressure; the volume must be known.
Why measure leaks?
Leaks run 24 hours a day; a plant losing 25 % of a 100 kW compressor's air wastes about 200 MWh a year.
What do the defaults represent?
An illustrative 10 m³ system falling from 8 to 6.5 bar absolute in 2 minutes, a 30 m³/min compressor at 6.5 kW per m³/min, 6,000 hours a year at 0.10 per kWh.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Brown, Compressors: Selection and Sizing, 3rd ed. (Gulf Professional, 2005)