Worked example
Example: 400 MPa at 10 % strain, RA 60 %. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Engineering stress | 400.00 MPa |
| Engineering strain | 10.000 % |
| Reduction of area at fracture | 60.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| True stress | 440.00 MPa |
| True strain | 9.5310 % |
| True fracture strain ln(1/(1 − RA)) | 91.629 % |
Open this example in the calculator and change any input.
Formula
\(\sigma_t = \sigma_e (1 + \varepsilon_e), \quad \varepsilon_t = \ln(1 + \varepsilon_e)\)
\(\varepsilon_f = \ln\frac{1}{1 - RA}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\sigma_e\) | Engineering stress | Pa |
| \(\varepsilon_e\) | Engineering strain | - |
| \(RA\) | Reduction of area at fracture | - |
| \(\sigma_t\) | True stress | Pa |
| \(\varepsilon_t\) | True strain | - |
| \(\varepsilon_f\) | True fracture strain ln(1/(1 − RA)) | - |
Method and standards
With volume constant during plastic flow, the current area is A₀/(1 + ε_e); this holds until necking, after which only the reduction of area gives true strain.
Where it is used
- Preparing flow curves for forming and FE models.
- Teaching tensile testing.
- Comparing ductility by true fracture strain.
Common mistakes
- Using the formulas after necking.
- Entering strain in per cent as a fraction.
- Mixing engineering and true values in one curve.
Assumptions and limits
- Uniform deformation, constant volume: valid only up to necking (the uniform elongation). Beyond it the conversion does not apply, although the input range allows larger strains.
References
- Constant-volume plastic deformation (Dieter, Mechanical Metallurgy, ch. 8)
Questions and answers
What true stress matches 400 MPa at 10 % strain?
440 MPa; the true strain is ln 1.1 = 0.0953.
Why are they different?
Engineering values use the original area and length; true values use the current ones, which change as the bar stretches and thins.
What is the true fracture strain?
ln(A₀/A_f) from the reduction of area: 60 % gives 0.92.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.