Worked example
Example: Illustrative home, net metering. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Monthly consumption | 600.00 kWh |
| Monthly solar generation | 450.00 kWh |
| Share of generation used directly | 40.000 % |
| Import tariff per kWh | 8.0000 - |
| Export (feed-in) rate per kWh | 3.5000 - |
| Fixed charges per month | 100.00 - |
| Scheme | Net metering (exports offset imports) |
Applying the formula below gives:
| Result | Value |
|---|---|
| Energy imported | 420.00 kWh |
| Energy exported | 270.00 kWh |
| Bill with solar | 1,300.0 |
| Bill without solar | 4,900.0 |
| Saving | 3,600.0 |
Open this example in the calculator and change any input.
Formula
\(E_{im} = E_c - f_sE_g, \quad E_{ex} = E_g(1 - f_s), \quad C_{net} = (E_{im} - E_{ex})r_i + C_f\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(E_c\) | Monthly consumption | J |
| \(E_g\) | Monthly solar generation | J |
| \(f_s\) | Share of generation used directly | - |
| \(r_i\) | Import tariff per kWh | - |
| \(r_x\) | Export (feed-in) rate per kWh | - |
| \(C_f\) | Fixed charges per month | - |
| \(\text{scheme}\) | Scheme | - |
| \(E_{im}\) | Energy imported | J |
| \(E_{ex}\) | Energy exported | J |
| \(C\) | Bill with solar | - |
| \(C_0\) | Bill without solar | - |
| \(\Delta C\) | Saving | - |
Method and standards
Net metering.
Where it is used
- Rooftop solar proposals.
- Comparing metering schemes.
Common mistakes
- Assuming exports earn the full tariff under net billing.
- Ignoring fixed charges.
Assumptions and limits
- Monthly settlement; flat tariff.
References
- Tariff arithmetic for net metering
- net billing and gross metering
Questions and answers
What is the bill for 600 kWh use and 450 kWh solar under net metering?
With 40 % self-use, 420 kWh imported and 270 exported: 150 net units, 1,300 with fixed charges against 4,900 without solar.
Why does self-consumption matter under net billing?
Each self-used unit saves the full tariff; an exported unit earns only the lower export rate.
What do the defaults represent?
An illustrative home using 600 kWh a month with 450 kWh of rooftop solar, 40 % used directly, tariff 8, export rate 3.5, fixed charges 100, net metering.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.