Worked example
Example: Rajasthan summer noon 42 C, 1,000 W/m2, NOCT 44 C, 4 m/s wind. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Ambient temperature | 42.000 °C |
| Irradiance on the module | 1,000.0 W/m² |
| Nominal operating cell temperature (data sheet) | 44.000 °C |
| Module efficiency at the operating point (first estimate) | 20.000 % |
| Transmittance-absorptance (about 0.9) | 90.000 % |
| Wind correction | Correct for wind speed |
| Wind speed | 4.0000 m/s |
| Module efficiency at 25 °C STC | 21.000 % |
| Power temperature coefficient (per K, e.g. 0.0035) | 0.003400 - |
| Module area | 2.0000 m² |
Applying the formula below gives:
| Result | Value |
|---|---|
| Cell temperature | 52.606 °C |
| Rise above ambient | 10.606 K |
| Module efficiency at the cell temperature | 19.029 % |
| Module output | 380.58 W |
Open this example in the calculator and change any input.
Formula
\(T_c - T_a = (T_{NOCT} - 20)\frac{G_T}{800}\left(1 - \frac{\eta_c}{\tau\alpha}\right)\ \left[\times\frac{9.5}{5.7 + 3.8V}\right]\)
\(\eta = \eta_{ref}[1 - \beta_{ref}(T_c - 25)]\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(T_a\) | Ambient temperature | K |
| \(G_T\) | Irradiance on the module | W/m² |
| \(T_{NOCT}\) | Nominal operating cell temperature (data sheet) | K |
| \(\eta_c\) | Module efficiency at the operating point (first estimate) | - |
| \((\tau\alpha)\) | Transmittance-absorptance (about 0.9) | - |
| \(\text{wind}\) | Wind correction | - |
| \(V\) | Wind speed | m/s |
| \(\eta_{ref}\) | Module efficiency at 25 °C STC | - |
| \(\beta_{ref}\) | Power temperature coefficient (per K, e.g. 0.0035) | - |
| \(A\) | Module area | m² |
| \(T_c\) | Cell temperature | K |
| \(T_c - T_a\) | Rise above ambient | K |
| \(\eta\) | Module efficiency at the cell temperature | - |
| \(P\) | Module output | W |
Method and standards
NOCT energy balance scaling of module temperature.
Where it is used
- PV yield in hot climates.
- String voltage checks at maximum cell temperature.
Common mistakes
- Using ambient temperature as cell temperature.
- Using the NOCT power rating as STC.
Assumptions and limits
- Open-rack mounting; roof-integrated modules run hotter.
Questions and answers
Why does cell temperature matter?
Crystalline silicon loses about 0.3–0.5 % of power per kelvin; cells run 20–40 K above ambient in full sun.
Where do I find NOCT and the temperature coefficient?
On the module data sheet; NOCT is typically 42–48 °C and the power coefficient −0.30 to −0.45 %/K.
What do the defaults represent?
An illustrative case: Rajasthan summer noon 42 C, 1,000 W/m2, NOCT 44 C, 4 m/s wind. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Duffie and Beckman, Solar Engineering of Thermal Processes, 4th ed. (Wiley, 2013), sec. 23.3, eqs. 23.3.3 and 23.3.4 and Example 23.3.1