FireCADCalc

Bifacial PV Rear-Side Gain

Rear-side irradiance, bifacial gain and module output of a bifacial PV module from front irradiance, ground albedo, a rear view factor and the module bifaciality.

Thermal power plant

Inputs

Examples: Illustrative 540 W over grassTracker over white gravel 0.5Snow 0.8, low sun

Accepted: 0.01 to 1.5 kW/m²
Accepted: 0.01 to 1.5 kW/m²
Accepted: 0 to 100 %
Accepted: 0 to 100 %
Accepted: 0 to 100 %
Accepted: 0.01 to 1 kW
Accepted: -0.01 to 0
Accepted: -40 to 90 °C

Results

Rear irradiance taken as ρ_g·F_r·G_h, with F_r lumping the view of the bright ground, row shading and structure; equivalent irradiance G_f + φG_r. Annual bifacial gains are about 5–10 % over grass and 10–20 % over bright ground on high trackers; use a view-factor or ray-tracing model for design.

Rear-side irradiance0.11000kW/m²
Bifacial gain φG_r/G_f8.5556%
Equivalent front irradiance0.97700kW/m²
Module output0.49065kW
Output if monofacial0.45198kW

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 540 W over grass. The inputs, in the units selected above:

InputValue
Front-side irradiance0.90000 kW/m²
Global horizontal irradiance reaching the ground0.80000 kW/m²
Ground albedo (grass 0.2, sand 0.3, white gravel or snow 0.5–0.8)25.000 %
Rear view and shading factor55.000 %
Bifaciality factor of the module70.000 %
Front-side rating at STC0.54000 kW
Power temperature coefficient (per K)-0.003500 -
Cell temperature45.000 °C

Applying the formula below gives:

ResultValue
Rear-side irradiance0.11000 kW/m²
Bifacial gain φG_r/G_f8.5556 %
Equivalent front irradiance0.97700 kW/m²
Module output0.49065 kW
Output if monofacial0.45198 kW

Open this example in the calculator and change any input.

Formula

\(G_r = \rho_gF_rG_h, \quad BG = \frac{\varphi G_r}{G_f}, \quad P = P_{STC}\frac{G_f + \varphi G_r}{1000}\left[1 + \gamma(T_c - 25)\right]\)

Variables

Symbol Meaning SI unit
\(G_f\) Front-side irradiance W/m²
\(G_h\) Global horizontal irradiance reaching the ground W/m²
\(\rho_g\) Ground albedo (grass 0.2, sand 0.3, white gravel or snow 0.5–0.8) -
\(F_r\) Rear view and shading factor -
\(\varphi\) Bifaciality factor of the module -
\(P_{STC}\) Front-side rating at STC W
\(\gamma\) Power temperature coefficient (per K) -
\(T_c\) Cell temperature K
\(G_r\) Rear-side irradiance W/m²
\(BG\) Bifacial gain φG_r/G_f -
\(G_{eq}\) Equivalent front irradiance W/m²
\(P\) Module output W
\(P_{mono}\) Output if monofacial W

Method and standards

Bifacial gain estimate.

Where it is used

  • Comparing monofacial and bifacial modules.
  • Ground treatment decisions under trackers.

Common mistakes

  • Using the albedo as the gain.
  • Ignoring rear shading by torque tubes and rails.

Assumptions and limits

  • Lumped rear factor; uniform rear irradiance.

References

  • Rear-side irradiance and bifacial gain

Questions and answers

How much extra does a bifacial module make?

Typically 5–10 % a year over grass and up to 15–20 % over white gravel, sand or snow on raised trackers.

What limits the rear gain?

Low mounting height, close rows, shading by the structure, and dark ground all reduce the light reaching the back.

What do the defaults represent?

An illustrative 540 W bifacial module at 900 W/m² on the front, 800 W/m² global horizontal, grass-like albedo 0.25, rear factor 0.55, bifaciality 0.70, 45 °C cell.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Gilbert Masters, Renewable and Efficient Electric Power Systems (Wiley, 2004), ch. 7

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.