Worked example
Example: Illustrative 5000 kWh/day, 0.2 %/day, 0.05, 1500 per clean. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Clean-array energy per day | 5,000.0 kWh |
| Soiling loss rate per day | 0.20000 % |
| Value of energy (currency per kWh) | 0.050000 - |
| Cost per cleaning (currency) | 1,500.0 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Optimum interval (days) | 77.460 |
| Average soiling loss at the optimum | 7.7460 % |
| Cost of soiling and cleaning per day | 38.730 |
| Cost per year | 14,136 |
| Cleanings per year | 4.7121 |
Open this example in the calculator and change any input.
Formula
\(T^* = \sqrt{\frac{2C}{Erc_e}}, \quad c_{day,min} = \sqrt{2CErc_e}, \quad \bar l = \frac{rT^*}{2}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(E\) | Clean-array energy per day | J |
| \(r\) | Soiling loss rate per day | - |
| \(c_e\) | Value of energy (currency per kWh) | - |
| \(C\) | Cost per cleaning (currency) | - |
| \(T^*\) | Optimum interval (days) | - |
| \(\bar l\) | Average soiling loss at the optimum | - |
| \(c_{day}\) | Cost of soiling and cleaning per day | - |
| \(c_{year}\) | Cost per year | - |
| \(n\) | Cleanings per year | - |
Method and standards
Cleaning optimisation.
Where it is used
- PV O&M planning in dusty climates.
- Comparing robotic and manual cleaning.
Common mistakes
- Using the wet-season soiling rate.
- Ignoring water and access costs in C.
Assumptions and limits
- Constant soiling rate; full recovery at each cleaning.
References
- Economic interval for a linearly growing loss
Questions and answers
How fast do panels get dirty?
From under 0.1 % a day in rainy climates to 0.5–1 % a day in deserts; dust storms add sudden steps.
Why a square root?
Losses grow with the interval while cleaning costs shrink with it; the balance gives T* proportional to √(C/(E r c_e)).
What do the defaults represent?
An illustrative plant making 5,000 kWh a day clean, soiling 0.2 % a day, energy worth 0.05 per kWh and 1,500 per cleaning.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Gilbert Masters, Renewable and Efficient Electric Power Systems (Wiley, 2004), ch. 9