Worked example
Example: Illustrative string inverter. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Efficiency at 5 % load | 92.000 % |
| Efficiency at 10 % load | 95.000 % |
| Efficiency at 20 % load | 97.000 % |
| Efficiency at 30 % load | 97.600 % |
| Efficiency at 50 % load | 97.900 % |
| Efficiency at 75 % load | 97.800 % |
| Efficiency at 100 % load | 97.500 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| European weighted efficiency | 97.322 % |
| CEC weighted efficiency | 97.630 % |
| Peak efficiency of the points entered | 97.900 % |
Open this example in the calculator and change any input.
Formula
\(\eta_{EU} = 0.03\eta_5 + 0.06\eta_{10} + 0.13\eta_{20} + 0.10\eta_{30} + 0.48\eta_{50} + 0.20\eta_{100}\)
\(\eta_{CEC} = 0.04\eta_{10} + 0.05\eta_{20} + 0.12\eta_{30} + 0.21\eta_{50} + 0.53\eta_{75} + 0.05\eta_{100}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\eta_{5}\) | Efficiency at 5 % load | - |
| \(\eta_{10}\) | Efficiency at 10 % load | - |
| \(\eta_{20}\) | Efficiency at 20 % load | - |
| \(\eta_{30}\) | Efficiency at 30 % load | - |
| \(\eta_{50}\) | Efficiency at 50 % load | - |
| \(\eta_{75}\) | Efficiency at 75 % load | - |
| \(\eta_{100}\) | Efficiency at 100 % load | - |
| \(\eta_{EU}\) | European weighted efficiency | - |
| \(\eta_{CEC}\) | CEC weighted efficiency | - |
| \(\eta_{max}\) | Peak efficiency of the points entered | - |
Method and standards
Weighted inverter efficiency.
Where it is used
- Comparing inverter offers.
- Inputs to PV loss budgets.
Common mistakes
- Using peak efficiency in yield estimates.
- Mixing efficiencies measured at different DC voltages.
Assumptions and limits
- Weights fixed by convention; one DC voltage.
References
- European and CEC weighted inverter efficiency
Questions and answers
Why weight the efficiency?
Inverters spend much of the year at part load; a weighted figure reflects the energy actually converted better than the peak efficiency.
Which weighting should I use?
European for cloudier climates and CEC for sunny ones; for a yield study use the full efficiency curve at the site.
What do the defaults represent?
An illustrative string inverter efficiency curve peaking near 97.9 % at half load.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Gilbert Masters, Renewable and Efficient Electric Power Systems (Wiley, 2004), ch. 9