Worked example
Example: Illustrative 1600 MWh, 2 % LID, 0.5 %/a, 25 a, 7 %. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Energy in the first year (before first-year degradation) | 1,600.0 MWh |
| First-year (light-induced) degradation | 2.0000 % |
| Annual degradation rate after year 1 | 0.50000 % |
| Plant life (years) | 25.000 - |
| Discount rate (for discounted energy) | 7.0000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Energy in the final year | 1,390.3 MWh |
| Final-year output relative to year 1 before losses | 86.892 % |
| Lifetime energy | 36,936 MWh |
| Average annual energy | 1,477.4 MWh |
| Discounted lifetime energy | 17,508 MWh |
Open this example in the calculator and change any input.
Formula
\(E_k = E_1(1 - l_1)(1 - d)^{k-1}, \quad \sum_{k=1}^{N}E_k, \quad \sum_{k=1}^{N}\frac{E_k}{(1 + r)^k}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(E_1\) | Energy in the first year (before first-year degradation) | J |
| \(l_1\) | First-year (light-induced) degradation | - |
| \(d\) | Annual degradation rate after year 1 | - |
| \(N\) | Plant life (years) | - |
| \(r\) | Discount rate (for discounted energy) | - |
| \(E_N\) | Energy in the final year | J |
| \(E_N/E_1\) | Final-year output relative to year 1 before losses | - |
| \(\sum E\) | Lifetime energy | J |
| \(\bar E\) | Average annual energy | J |
| \(\sum E/(1 + r)^n\) | Discounted lifetime energy | J |
Method and standards
Degradation and discounting.
Where it is used
- Financial models and warranty checks.
- Repowering decisions.
Common mistakes
- Applying degradation from year 0.
- Mixing discounted and undiscounted energy in LCOE.
Assumptions and limits
- Constant degradation rate; no repowering.
References
- Geometric degradation of PV output
Questions and answers
How much does a panel degrade?
Typically 1–3 % in the first months (light-induced) and about 0.5 % per year after that; after 25 years output is about 86 % of the first year.
Why discount energy?
Levelised cost divides discounted costs by discounted energy; later kilowatt-hours count for less in present-value terms.
What do the defaults represent?
An illustrative 1 MWp plant making 1,600 MWh in year one, 2 % first-year loss, 0.5 % per year, 25 years and a 7 % discount rate.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Gilbert Masters, Renewable and Efficient Electric Power Systems (Wiley, 2004), ch. 5