Worked example
Example: Cogeneration 50 M capital, 2 M O&M, 15 M fuel, 8 GWh, 10 %, 15 years. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Capital cost (your currency) | 5.0000e+07 - |
| Operation and maintenance per year | 2,000,000 - |
| Fuel cost per year | 1.5000e+07 - |
| Output per year (kWh of power or heat, or tonnes of steam) | 8,000,000 - |
| Interest (discount) rate | 10.000 % |
| Life, years | 15.000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Capital recovery factor (per year) | 0.13147 |
| Capital cost per year | 6,573,689 |
| Total cost per year | 2.3574e+07 |
| Levelised cost per unit of output | 2.9467 |
Open this example in the calculator and change any input.
Formula
\(CRF = \frac{i (1+i)^n}{(1+i)^n - 1}\)
\(C_y = C_0\, CRF + C_{OM} + C_F\)
\(LCOE = C_y / E_y\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(C_0\) | capital cost | currency |
| \(C_{OM}\) | O&M per year | currency |
| \(C_F\) | fuel per year | currency |
| \(E_y\) | output per year | unit |
| \(i\) | interest rate | - |
| \(n\) | life | years |
| \(CRF\) | capital recovery factor | 1/year |
| \(C_0 CRF\) | capital cost per year | currency |
| \(C_y\) | total cost per year | currency |
| \(LCOE\) | levelised cost | currency/unit |
Method and standards
The capital is turned into an equal yearly payment by the capital recovery factor; adding yearly operating and fuel costs and dividing by yearly output gives the levelised cost.
Where it is used
- Comparing power, steam or heat options.
- Pricing internal steam and power.
- Screening solar, cogeneration and boiler projects.
Common mistakes
- Mixing nominal and real interest rates.
- Using nameplate output instead of expected output.
- Leaving out major overhauls.
Assumptions and limits
- Constant yearly costs and output.
References
- Capital recovery factor method
Questions and answers
What is the LCOE of the example cogeneration plant?
About 2.95 per kWh: 50 M capital at 10 % over 15 years is 6.57 M a year, plus 2 M O&M and 15 M fuel, over 8 GWh.
Can I use it for steam?
Yes: enter yearly steam in tonnes as the output and the result is cost per tonne.
What does it leave out?
Price escalation, varying output, taxes and residual value; use a year-by-year cash flow for those.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.