Worked example
Example: Cheap short-life vs dear long-life. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Option A capital cost | 1,500,000 - |
| Option A annual running cost | 600,000 - |
| Option A life (years) | 8.0000 - |
| Option A salvage | 100,000 - |
| Option B capital cost | 2,600,000 - |
| Option B annual running cost | 420,000 - |
| Option B life (years) | 15.000 - |
| Option B salvage | 200,000 - |
| Discount rate | 10.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Option A equivalent annual cost | 872,422 |
| Option B equivalent annual cost | 755,537 |
| Cheaper option (1 = A, 2 = B) | 2.0000 |
Open this example in the calculator and change any input.
Formula
\(EAC = C\frac{i(1 + i)^n}{(1 + i)^n - 1} - S\frac{i}{(1 + i)^n - 1} + O\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(C_A\) | Option A capital cost | - |
| \(O_A\) | Option A annual running cost | - |
| \(n_A\) | Option A life (years) | - |
| \(S_A\) | Option A salvage | - |
| \(C_B\) | Option B capital cost | - |
| \(O_B\) | Option B annual running cost | - |
| \(n_B\) | Option B life (years) | - |
| \(S_B\) | Option B salvage | - |
| \(i\) | Discount rate | - |
| \(EAC_A\) | Option A equivalent annual cost | - |
| \(EAC_B\) | Option B equivalent annual cost | - |
| \(\text{best}\) | Cheaper option (1 = A, 2 = B) | - |
Method and standards
Annual worth.
Where it is used
- Pump, motor and boiler choices.
- Lease vs buy screening.
Common mistakes
- Comparing NPVs over different lives.
- Ignoring salvage.
Assumptions and limits
- Like-for-like replacement.
- At a zero discount rate EAC = (C − S)/n + O.
References
- EAC = C·CRF − S·SFF + O (engineering economics, annual worth method)
Questions and answers
Option A 15 lakh for 8 years vs B 26 lakh for 15 years at 10 %?
A about 872,422 a year, B about 755,537: B is cheaper.
Why not compare NPVs?
Different lives make NPVs incomparable; EAC fixes that.
Salvage?
It reduces the annual cost through the sinking fund factor.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.