Worked example
Example: Oil to biomass. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Old fuel price per kg | 70.000 - |
| Old fuel calorific value (same GCV or NCV basis as η₁) | 41.000 MJ/kg |
| Efficiency on the old fuel | 86.000 % |
| New fuel calorific value (same basis as CV₁ and η₂) | 15.500 MJ/kg |
| Efficiency on the new fuel | 78.000 % |
| Useful heat per year | 60,000 GJ |
| Conversion cost | 3.0000e+07 - |
| Interest rate | 10.000 % |
| Recovery period (years) | 7.0000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Old fuel per year | 1,701.6 t |
| New fuel per year | 4,962.8 t |
| Capital recovery factor | 20.541 % |
| Break-even new fuel price per kg | 22.760 |
Open this example in the calculator and change any input.
Formula
\(p_{2,be} = \frac{m_1 p_1 - C_0\,CRF}{m_2}, \quad m_i = \frac{Q}{\eta_i CV_i}, \quad CRF = \frac{i(1 + i)^n}{(1 + i)^n - 1}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(p_1\) | Old fuel price per kg | - |
| \(CV_1\) | Old fuel calorific value (same GCV or NCV basis as η₁) | J/kg |
| \(\eta_1\) | Efficiency on the old fuel | - |
| \(CV_2\) | New fuel calorific value (same basis as CV₁ and η₂) | J/kg |
| \(\eta_2\) | Efficiency on the new fuel | - |
| \(Q\) | Useful heat per year | J |
| \(C_0\) | Conversion cost | - |
| \(i\) | Interest rate | - |
| \(n\) | Recovery period (years) | - |
| \(m_1\) | Old fuel per year | kg |
| \(m_2\) | New fuel per year | kg |
| \(CRF\) | Capital recovery factor | - |
| \(p_{2,be}\) | Break-even new fuel price per kg | - |
Method and standards
Annual cost balance.
Where it is used
- Coal, oil, gas and biomass switching studies.
- Fuel contract negotiation.
Common mistakes
- Gross vs net CV mixed.
- Ignoring handling costs.
Assumptions and limits
- Constant prices.
- Both calorific values and both efficiencies on one basis (all GCV or all NCV).
- A negative break-even price (conversion cost above the old fuel bill) is flagged.
References
- Equal annual cost: m₁p₁ = m₂p₂ + C₀·CRF
- with m = Q/(η CV)
Questions and answers
Oil at 70/kg to biomass, 60,000 GJ a year, 3 crore conversion?
Biomass pays below about 22.8 per kg.
Why include the CRF?
It spreads the conversion cost into a yearly charge with interest.
Lower efficiency on the new fuel?
It raises the fuel quantity and lowers the break-even price.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.