Worked example
Example: Illustrative 50 m3/day, 40 m. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Water volume per day | 50.000 m³ |
| Total dynamic head | 40.000 m |
| Pump and motor (and controller) efficiency | 45.000 % |
| Peak sun hours on the array (kWh/m² per day) | 5.5000 - |
| Array derate (temperature, soiling, wiring) | 80.000 % |
| Water density | 1,000.0 kg/m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Hydraulic energy per day | 5.4481 kWh |
| Electrical energy per day | 12.107 kWh |
| PV array size (DC, at STC) | 2.7516 kW |
| Average flow over the peak sun hours | 9.0909 m³/h |
| Average hydraulic power | 0.99057 kW |
Open this example in the calculator and change any input.
Formula
\(E_h = \rho gHV_d, \quad P_{PV} = \frac{E_h}{\eta_p\,PSH\,f}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(V_d\) | Water volume per day | m³ |
| \(H\) | Total dynamic head | m |
| \(\eta_p\) | Pump and motor (and controller) efficiency | - |
| \(PSH\) | Peak sun hours on the array (kWh/m² per day) | - |
| \(f\) | Array derate (temperature, soiling, wiring) | - |
| \(\rho\) | Water density | kg/m³ |
| \(E_h\) | Hydraulic energy per day | J |
| \(E_e\) | Electrical energy per day | J |
| \(P_{PV}\) | PV array size (DC, at STC) | W |
| \(\bar Q\) | Average flow over the peak sun hours | m³/s |
| \(P_h\) | Average hydraulic power | W |
Method and standards
Solar pumping energy balance.
Where it is used
- Irrigation, livestock and village water supply.
- Replacing diesel pumps.
Common mistakes
- Using static lift instead of total dynamic head.
- Sizing for the annual average sun instead of the worst month.
Assumptions and limits
- Daily energy balance; pump efficiency constant over the day.
References
- Hydraulic energy and PV array sizing for direct pumping
Questions and answers
How much PV does a pump need?
About 2.4 kWh of electricity per day per 10 m³ lifted 40 m at 45 % pump efficiency, so roughly 0.55 kWp per 10 m³/day with 5.5 peak sun hours and an 80 % derate.
Why use a tank instead of batteries?
Storing water is cheaper and lasts longer than storing electricity; the pump simply runs when the sun shines.
What do the defaults represent?
An illustrative 50 m³ per day against 40 m head with a 45 % efficient pump set, 5.5 peak sun hours and an 80 % derate.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Gilbert Masters, Renewable and Efficient Electric Power Systems (Wiley, 2004), ch. 9