FireCADCalc

Thickener Area by the Talmage–Fitch Method

Thickener unit area and diameter from a batch settling test by the simplified Talmage–Fitch construction, with the underflow line height and a safety factor.

Inputs

Examples: Copper tailings 400 t/h, 25 % feed solidsConcentrate thickener 40 t/hCoal tailings, flocculated

Results

Draw H_u = C₀H₀/C_u on the settling curve; t_u is where the tangent at the compression point crosses it (or where the curve crosses it if compression starts below C_u). Use a flocculated test if the plant will flocculate.

Thickener area (test)1,944.4m²
Design area with safety factor2,527.8m²
Thickener diameter56.732m
Unit area (m² per t/d)0.26331
Height of the underflow line on the settling curve10.000cm

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Copper tailings 400 t/h, 25 % feed solids. The inputs, in the units selected above:

InputValue
Dry solids feed rate400.00 t/h
Feed solids concentration in the test300.00 g/L
Initial slurry height in the test40.000 cm
Time to reach the underflow concentration (from the tangent)35.000 min
Target underflow concentration1,200.0 g/L
Scale-up safety factor (1.2–1.5)1.3000 -

Applying the formula below gives:

ResultValue
Thickener area (test)1,944.4 m²
Design area with safety factor2,527.8 m²
Thickener diameter56.732 m
Unit area (m² per t/d)0.26331
Height of the underflow line on the settling curve10.000 cm

Open this example in the calculator and change any input.

Formula

\(A = \frac{W t_u}{C_0 H_0}, \quad H_u = \frac{C_0 H_0}{C_u}, \quad D = \sqrt{\frac{4 f_s A}{\pi}}\)

Variables

Symbol Meaning SI unit
\(W\) Dry solids feed rate kg/s
\(C_0\) Feed solids concentration in the test kg/m³
\(H_0\) Initial slurry height in the test m
\(t_u\) Time to reach the underflow concentration (from the tangent) s
\(C_u\) Target underflow concentration kg/m³
\(f_s\) Scale-up safety factor (1.2–1.5) -
\(A\) Thickener area (test) m²
\(A_d\) Design area with safety factor m²
\(D\) Thickener diameter m
\(A_d/W\) Unit area (m² per t/d) -
\(H_u\) Height of the underflow line on the settling curve m

Method and standards

Simplified Talmage–Fitch construction.

Where it is used

  • Sizing tailings and concentrate thickeners.
  • Rating a thickener for higher throughput.

Common mistakes

  • Using the clear-water settling rate.
  • Mixing concentration in g/L with t/m³ inconsistently.

Assumptions and limits

  • Kynch theory; batch test representative of the plant.

References

  • Wills and Finch
  • Wills' Mineral Processing Technology
  • 8th ed. (Butterworth-Heinemann, 2016)
  • ch. 15
  • eqs. 15.4-15.6 (Talmage and Fitch, 1955)

Questions and answers

How does it differ from Coe–Clevenger?

Talmage–Fitch uses one batch settling curve and Kynch's theory instead of several tests at different dilutions.

Why a safety factor?

Small-cylinder tests and the tangent construction are uncertain; Wills cites 1.2–1.5 on area.

What do the defaults represent?

400 t/h of copper tailings tested at 300 g/L from 0.40 m, reaching the 1,200 g/L underflow line after 35 minutes, with a factor of 1.3.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.