Worked example
Example: Copper tailings 400 t/h, 25 % feed solids. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Dry solids feed rate | 400.00 t/h |
| Feed solids concentration in the test | 300.00 g/L |
| Initial slurry height in the test | 40.000 cm |
| Time to reach the underflow concentration (from the tangent) | 35.000 min |
| Target underflow concentration | 1,200.0 g/L |
| Scale-up safety factor (1.2–1.5) | 1.3000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Thickener area (test) | 1,944.4 m² |
| Design area with safety factor | 2,527.8 m² |
| Thickener diameter | 56.732 m |
| Unit area (m² per t/d) | 0.26331 |
| Height of the underflow line on the settling curve | 10.000 cm |
Open this example in the calculator and change any input.
Formula
\(A = \frac{W t_u}{C_0 H_0}, \quad H_u = \frac{C_0 H_0}{C_u}, \quad D = \sqrt{\frac{4 f_s A}{\pi}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(W\) | Dry solids feed rate | kg/s |
| \(C_0\) | Feed solids concentration in the test | kg/m³ |
| \(H_0\) | Initial slurry height in the test | m |
| \(t_u\) | Time to reach the underflow concentration (from the tangent) | s |
| \(C_u\) | Target underflow concentration | kg/m³ |
| \(f_s\) | Scale-up safety factor (1.2–1.5) | - |
| \(A\) | Thickener area (test) | m² |
| \(A_d\) | Design area with safety factor | m² |
| \(D\) | Thickener diameter | m |
| \(A_d/W\) | Unit area (m² per t/d) | - |
| \(H_u\) | Height of the underflow line on the settling curve | m |
Method and standards
Simplified Talmage–Fitch construction.
Where it is used
- Sizing tailings and concentrate thickeners.
- Rating a thickener for higher throughput.
Common mistakes
- Using the clear-water settling rate.
- Mixing concentration in g/L with t/m³ inconsistently.
Assumptions and limits
- Kynch theory; batch test representative of the plant.
References
- Wills and Finch
- Wills' Mineral Processing Technology
- 8th ed. (Butterworth-Heinemann, 2016)
- ch. 15
- eqs. 15.4-15.6 (Talmage and Fitch, 1955)
Questions and answers
How does it differ from Coe–Clevenger?
Talmage–Fitch uses one batch settling curve and Kynch's theory instead of several tests at different dilutions.
Why a safety factor?
Small-cylinder tests and the tangent construction are uncertain; Wills cites 1.2–1.5 on area.
What do the defaults represent?
400 t/h of copper tailings tested at 300 g/L from 0.40 m, reaching the 1,200 g/L underflow line after 35 minutes, with a factor of 1.3.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.