FireCADCalc

Hydrocyclone Scale-Up: Cut Size and Pressure Drop

Cut size and pressure drop of a larger hydrocyclone scaled from a tested one by flow and diameter, the diameter for equal cut size, and the hydraulic power.

Inputs

Examples: 100 mm test cyclone to 380 mm plant cycloneSame, theoretical exponents250 mm to 500 mm at higher flow

Results

Scale-up holds for geometrically similar cyclones on the same slurry; high solids raise the cut size and lower the pressure drop at a given flow. Cut size, flow and pressure must be considered together.

New corrected cut size40.955µm
New pressure drop120.23kPa
Diameter giving the tested cut size at the new pressure10.965cm
Hydraulic power per cyclone3.8073kW
Flow by Wills's approximation 9.5×10⁻³ D_c² √P150.42m³/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 100 mm test cyclone to 380 mm plant cyclone. The inputs, in the units selected above:

InputValue
Tested cyclone diameter10.000 cm
Tested flow per cyclone120.00 L/min
Tested pressure drop100.00 kPa
Tested corrected cut size22.000 µm
New cyclone diameter38.000 cm
New flow per cyclone1,900.0 L/min
ExponentsPractical (Wills): 1.54, 0.43, 0.72, 0.22, 2.0, 3.76

Applying the formula below gives:

ResultValue
New corrected cut size52.417 µm
New pressure drop165.64 kPa
Diameter giving the tested cut size at the new pressure11.667 cm
Hydraulic power per cyclone5.2452 kW
Flow by Wills's approximation 9.5×10⁻³ D_c² √P176.55 m³/h

Open this example in the calculator and change any input.

Formula

\(\frac{d_{50c2}}{d_{50c1}} = \left(\frac{D_{c2}}{D_{c1}}\right)^{n_1}\left(\frac{Q_1}{Q_2}\right)^{n_2}, \quad \frac{P_1}{P_2} = \left(\frac{Q_1}{Q_2}\right)^{n_5}\left(\frac{D_{c2}}{D_{c1}}\right)^{n_6}, \quad D_c^* = D_{c1}\left(\frac{P_2}{P_1}\right)^{n_4/n_3}\)

Variables

Symbol Meaning SI unit
\(D_{c1}\) Tested cyclone diameter m
\(Q_1\) Tested flow per cyclone m³/s
\(P_1\) Tested pressure drop Pa
\(d_{50c1}\) Tested corrected cut size m
\(D_{c2}\) New cyclone diameter m
\(Q_2\) New flow per cyclone m³/s
\(n_i\) Exponents -
\(d_{50c2}\) New corrected cut size m
\(P_2\) New pressure drop Pa
\(D_c^*\) Diameter giving the tested cut size at the new pressure m
\(P_2 Q_2\) Hydraulic power per cyclone W
\(Q_{app}\) Flow by Wills's approximation 9.5×10⁻³ D_c² √P m³/s

Method and standards

Power-law scale-up of geometrically similar cyclones.

Where it is used

  • Selecting plant cyclones from pilot tests.
  • Checking the pressure for a new cyclone cluster.

Common mistakes

  • Mixing total and per-cyclone flow.
  • Scaling between cyclones of different geometry.

Assumptions and limits

  • Geometric similarity; same slurry.

References

  • Wills and Finch
  • Wills' Mineral Processing Technology
  • 8th ed. (Butterworth-Heinemann, 2016)
  • ch. 9
  • eqs. 9.24-9.27

Questions and answers

Why can't cut size be scaled on diameter alone?

A new diameter brings a new flow or pressure or both; the three must be chosen together.

Which exponents should I use?

Wills recommends the practical set for most plant slurries; the theoretical set holds for dilute laminar flow in small cyclones.

What do the defaults represent?

A 100 mm test cyclone cutting at 22 µm with 120 L/min and 100 kPa, scaled to a 380 mm cyclone taking 1,900 L/min.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.