Flow over a Rectangular or V-Notch Weir

Flow over a sharp-crested rectangular or V-notch (triangular) weir from the head over the crest and the discharge coefficient, and the head for a target flow.

Condenser and cooling tower

Inputs

Examples: 90° V-notch, 200 mm head, Cd 0.59Rectangular 1 m crest, 150 mm head, Cd 0.62, head for 0.2 m³/s60° V-notch, 120 mm, Cd 0.58, head for 5 L/s

About 0.6 for sharp-crested weirs; calibrate or take it from the weir standard for accurate metering.

Results

Free (aerated) nappe and negligible approach velocity; end contractions are taken into the coefficient.

Flow over the weir106.34L/s
Head for the target flow228.54mm

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 90° V-notch, 200 mm head, Cd 0.59. The inputs, in the units selected above:

InputValue
Weir typeV-notch (triangular)
Crest width (rectangular)1.0000 m
Notch angle (V-notch)90.000 °
Head over the crest or notch bottom200.00 mm
Discharge coefficient0.59000 -
Target flow for the head output (0 = none)0 m³/h

Applying the formula below gives:

ResultValue
Flow over the weir24.929 L/s

Open this example in the calculator and change any input.

Formula

\(Q = \frac{2}{3} C_d\, b \sqrt{2g}\, H^{3/2} \ \text{(rectangular)}\)

\(Q = \frac{8}{15} C_d \tan\frac{\theta}{2} \sqrt{2g}\, H^{5/2} \ \text{(V-notch)}\)

Variables

Symbol Meaning SI unit
\(\text{type}\) weir type -
\(b\) crest width m
\(\theta\) notch angle rad
\(H\) head over the crest m
\(C_d\) discharge coefficient -
\(Q_t\) target flow m³/s
\(Q\) flow over the weir m³/s
\(H_t\) head for the target flow m
\(g\) standard gravity m/s²

Method and standards

Integrating the ideal velocity √(2gh) over the opening gives the weir equations; the discharge coefficient accounts for contraction and losses. The head for a target flow inverts the same equation.

Where it is used

  • Measuring effluent and cooling tower blowdown flows.
  • Sizing weirs in tanks and channels.
  • Checking clarifier and settling tank outlets.

Common mistakes

  • Measuring head too close to the weir (the surface draws down).
  • Letting the nappe cling to the weir (it must be aerated).
  • Using the coefficient for a different notch angle.

Assumptions and limits

  • One constant discharge coefficient is used at every head. Standard weir methods (Kindsvater–Carter, ISO 1438) make the coefficient depend on head, crest height and width ratio, add an approach-velocity correction and set limits on head and dimensions; none of these is applied, so for metering use a calibrated coefficient or the standard's method.

  • Free, aerated nappe; approach velocity negligible.

References

  • Sharp-crested weir equations

Questions and answers

What flow does a 90° V-notch pass at 200 mm head?

About 24.9 L/s with Cd 0.59.

Why use a V-notch for small flows?

Flow rises with head to the power 2.5, so small flows still give a readable head.

What coefficient should I use?

About 0.6 for sharp-crested weirs; for accurate metering use the coefficient for your weir's geometry from the weir standard or a calibration.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.