Meyer (1915): E = C(e_w − e_a)(1 + u₉/16), E in mm/day, e in mm of mercury, u₉ in km/h at 9 m. Saturation pressures from IAPWS-IF97.

Saturation vapour pressure at water temperature35.697mmHg
Air vapour pressure12.665mmHg
Evaporation (mm/day)21.880
Volume lost per day4,376.1m³

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 100 ha reservoir, 27/30 °C, 50 %, 3 m/s. The inputs, in the units selected above:

InputValue
Water surface temperature27.000 °C
Air temperature30.000 °C
Relative humidity50.000 %
Wind speed at 9 m3.0000 m/s
Meyer coefficient (0.36 large deep, 0.50 small shallow)0.36000 -
Water surface area100.00 ha

Applying the formula below gives:

ResultValue
Saturation vapour pressure at water temperature26.761 mmHg
Air vapour pressure15.926 mmHg
Evaporation (mm/day)6.5335
Volume lost per day6,533.5 m³

Open this example in the calculator and change any input.

Formula

\(E = C(e_w - e_a)\left(1 + \frac{u_9}{16}\right)\ \ (\mathrm{mm/day};\ e\ \mathrm{in\ mm\ Hg};\ u_9\ \mathrm{in\ km/h})\)

Variables

Symbol Meaning SI unit
\(t_w\) Water surface temperature K
\(t_a\) Air temperature K
\(\varphi\) Relative humidity -
\(u_9\) Wind speed at 9 m m/s
\(C\) Meyer coefficient (0.36 large deep, 0.50 small shallow) -
\(A\) Water surface area m²
\(e_w\) Saturation vapour pressure at water temperature Pa
\(e_a\) Air vapour pressure Pa
\(E\) Evaporation (mm/day) -
\(V_d\) Volume lost per day m³

Method and standards

Meyer's formula.

Where it is used

  • Raw-water reservoir and ash pond balances.
  • Cooling pond water budgets.

Common mistakes

  • Using air temperature for e_w.
  • Wind at the wrong height.

Assumptions and limits

  • Daily averages.

References

  • Meyer's formula (Subramanya, Engineering Hydrology, ch. 3); IAPWS-IF97 saturation pressure

Questions and answers

How large is reservoir evaporation in India?

Typically 3–8 mm per day in summer, a significant share of small raw-water ponds.

How can evaporation be reduced?

Deeper, smaller-area storage, windbreaks, floating covers or monolayers.

What do the defaults represent?

A 100 ha raw-water reservoir on a warm, moderately dry day.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.