FireCADCalc

Gravity Dam Stability: Overturning, Sliding and Base Pressure

Factors of safety against overturning and sliding and base pressures of a gravity dam with a vertical upstream face, from geometry, water and uplift.

Thermal power plantSugar mill and cogenerationPulp and paper

Inputs

Examples: 25 m dam, 4 m top, 20 m base, 24 m waterSmall check dam 6 m, full upliftSlender section, heel cracks

Results

Per metre length; water 9.81 kN/m³; triangular uplift from c·γ_wh_w at the heel to zero at the toe. No tension at the heel requires e ≤ B/6. Earthquake, silt and wave loads are not included.

Factor of safety against overturning2.4135
Factor of safety against sliding1.4551
Eccentricity of the resultant (toward the toe)0.78206m
Base pressure at the toe362.53kPa
Base pressure at the heel224.75kPa

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 25 m dam, 4 m top, 20 m base, 24 m water. The inputs, in the units selected above:

InputValue
Top width4.0000 m
Base width20.000 m
Dam height25.000 m
Upstream water depth24.000 m
Unit weight of masonry or concrete23.500 kN/m³
Uplift intensity factor at the heel50.000 %
Friction coefficient at the base0.70000 -

Applying the formula below gives:

ResultValue
Factor of safety against overturning2.4135
Factor of safety against sliding1.4551
Eccentricity of the resultant (toward the toe)0.78206 m
Base pressure at the toe362.53 kPa
Base pressure at the heel224.75 kPa

Open this example in the calculator and change any input.

Formula

\(FS_o = \frac{\sum M_R}{\sum M_O}, \quad FS_s = \frac{\mu(\sum W - U)}{P}, \quad p = \frac{V}{B}\left(1 \pm \frac{6e}{B}\right)\)

When \(e > B/6\) the heel would be in tension; the base is taken as cracked, with the resultant at \(x = B/2 - e\) from the toe:

\(p_{toe} = \frac{2V}{3x}, \quad p_{heel} = 0\)

Variables

Symbol Meaning SI unit
\(b\) Top width m
\(B\) Base width m
\(H\) Dam height m
\(h_w\) Upstream water depth m
\(\gamma_c\) Unit weight of masonry or concrete N/m³
\(c\) Uplift intensity factor at the heel -
\(\mu\) Friction coefficient at the base -
\(FS_o\) Factor of safety against overturning -
\(FS_s\) Factor of safety against sliding -
\(e\) Eccentricity of the resultant (toward the toe) m
\(p_{toe}\) Base pressure at the toe Pa
\(p_{heel}\) Base pressure at the heel Pa

Method and standards

Statics of the dam section.

Where it is used

  • Check dams, weirs and small gravity dams.
  • Ash pond and reservoir structures.

Common mistakes

  • Ignoring uplift.
  • Using a friction factor without shear-key benefit justification.

Assumptions and limits

  • Static loads; rigid section; per metre length.

References

  • Elementary profile analysis of gravity dams (Garg, Irrigation Engineering and Hydraulic Structures (Khanna), ch. on gravity dams)

Questions and answers

Why is uplift important?

Water seeping under the dam pushes up and reduces the effective weight; drains reduce the uplift factor.

What does e ≤ B/6 mean?

The resultant stays in the middle third, so the whole base stays in compression.

What do the defaults represent?

A 25 m masonry dam, 4 m top and 20 m base, holding 24 m of water with half uplift.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.