FireCADCalc

Masonry Wall Load per Metre on a Beam or Slab

Line load of a brick or block wall with plaster on both faces per metre run, reduced for openings, and as an area load for partition allowances.

Inputs

Examples: Illustrative 230 mm brick wall, 3 m115 mm partition, 3 m200 mm AAC block, openings

Accepted: 50 to 1,000 mm
Accepted: 0.3 to 10 m
Accepted: 500 to 2,500 kg/m³
Accepted: 0 to 50 mm
Accepted: 1,000 to 2,500 kg/m³
Accepted: 0 to 80 %

Results

The wall weighs its density times thickness per square metre of face, plus plaster on both faces; times the height it is a line load on the supporting beam or slab. A 230 mm brick wall 3 m high with 12 mm plaster weighs about 14.4 kN/m. Openings reduce it, but lintels carry the load above them to the jambs, so use the reduction with care. Partitions of uncertain position on slabs are often taken as an equivalent area load instead.

Line load4.3482kN/m
Wall weight per square metre of face1.6985kPa

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 230 mm brick wall, 3 m. The inputs, in the units selected above:

InputValue
Wall thickness (without plaster)230.00 mm
Wall height3.0000 m
Masonry density1,920.0 kg/m³
Plaster thickness each face12.000 mm
Plaster density2,000.0 kg/m³
Openings as a share of wall area0 %

Applying the formula below gives:

ResultValue
Line load14.404 kN/m
Wall weight per square metre of face4.8013 kPa

Open this example in the calculator and change any input.

Formula

\(q = (\rho t + 2\rho_p t_p)g, \quad w = q\,h(1 - f_o)\)

Variables

Symbol Meaning SI unit
\(t\) Wall thickness (without plaster) m
\(h\) Wall height m
\(\rho\) Masonry density kg/m³
\(t_p\) Plaster thickness each face m
\(\rho_p\) Plaster density kg/m³
\(f_o\) Openings as a share of wall area -
\(w\) Line load N/m
\(q\) Wall weight per square metre of face Pa

Method and standards

Wall load.

Where it is used

  • Beam and slab design.
  • Checking loads on existing structures.

Common mistakes

  • Forgetting plaster.
  • Deducting openings fully.

Assumptions and limits

  • Uniform wall; unit weights as entered.

References

  • Dead load from unit weights

Questions and answers

What load does a 230 mm brick wall 3 m high put on a beam?

About 14.4 kN/m with 12 mm plaster both faces.

Should openings be deducted?

Partly: lintels carry the load above openings to the jambs.

What do the defaults represent?

An illustrative 230 mm brick wall, 3 m high, density 1,920 kg/m³, with 12 mm plaster on each face and no openings.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.