FireCADCalc

Flexural Crack Width (Gergely–Lutz)

Probable maximum flexural crack width at the tension face of a reinforced concrete beam from the steel stress, cover and bar spacing, by the Gergely–Lutz equation.

Inputs

Examples: Illustrative beam, four barsSlab strip, close barsDeep beam, two large bars

Accepted: 50 to 500 MPa
Accepted: 10 to 200 mm
Accepted: 100 to 3,000 mm
Accepted: 1 to 50
Accepted: 100 to 3,000 mm
Accepted: 100 to 3,000 mm
Accepted: 10 to 2,000 mm

Results

Gergely and Lutz fitted measured crack widths: w = 11 × 10⁻⁶ β f_s ∛(d_c A) in mm, with f_s in MPa, d_c in mm and A = 2 d_c b/n in mm². Widths grow with steel stress and cover; many smaller bars give finer cracks than a few large ones. Typical limits are 0.3 mm for interior exposure and 0.1–0.2 mm for water-retaining or aggressive exposure. Crack widths scatter widely: treat the result as a probable maximum, not a guarantee.

Effective tension area of concrete per bar7,500.0mm²
Strain gradient factor (h − x)/(d − x)1.1316
Probable maximum crack width0.21543mm

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative beam, four bars. The inputs, in the units selected above:

InputValue
Steel stress at service load240.00 MPa
Cover to the centre of the bar nearest the tension face50.000 mm
Width of the tension zone300.00 mm
Number of bars4.0000 -
Overall depth600.00 mm
Effective depth550.00 mm
Neutral axis depth at service load (cracked elastic)170.00 mm

Applying the formula below gives:

ResultValue
Effective tension area of concrete per bar7,500.0 mm²
Strain gradient factor (h − x)/(d − x)1.1316
Probable maximum crack width0.21543 mm

Open this example in the calculator and change any input.

Formula

\(w = 11\times10^{-6}\,\beta\,f_s\sqrt[3]{d_c A}\ \ \text{(mm, MPa, mm}^2\text{)}, \quad A = \frac{2 d_c b}{n}, \quad \beta = \frac{h - x}{d - x}\)

Variables

Symbol Meaning SI unit
\(f_s\) Steel stress at service load Pa
\(d_c\) Cover to the centre of the bar nearest the tension face m
\(b\) Width of the tension zone m
\(n\) Number of bars -
\(h\) Overall depth m
\(d\) Effective depth m
\(x\) Neutral axis depth at service load (cracked elastic) m
\(A\) Effective tension area of concrete per bar m²
\(\beta\) Strain gradient factor (h − x)/(d − x) -
\(w\) Probable maximum crack width m

Method and standards

Crack width.

Where it is used

  • Serviceability checks of beams and slabs.
  • Water-retaining structures.

Common mistakes

  • Using the clear cover instead of the cover to the bar centre.
  • Taking the ultimate steel stress.

Assumptions and limits

  • Flexural cracks at the tension face; one layer of bars.

References

  • Gergely–Lutz crack width equation (SI form)

Questions and answers

How do I reduce crack width?

Use more, smaller bars at closer spacing, less cover where allowed, or lower service steel stress.

Where do f_s and x come from?

From a cracked elastic section analysis at service load; the cracked-section calculator gives both.

What do the defaults represent?

An illustrative 300 × 600 mm beam, d = 550 mm, 4 bars with 50 mm to their centres, 240 MPa service stress, neutral axis 170 mm.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Gergely and Lutz, Maximum crack width in reinforced concrete flexural members, ACI SP-20 (1968)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.