Worked example
Example: Illustrative 230 mm brick wall, 3 m. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Wall thickness (without plaster) | 230.00 mm |
| Wall height | 3.0000 m |
| Masonry density | 1,920.0 kg/m³ |
| Plaster thickness each face | 12.000 mm |
| Plaster density | 2,000.0 kg/m³ |
| Openings as a share of wall area | 0 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Line load | 14.404 kN/m |
| Wall weight per square metre of face | 4.8013 kPa |
Open this example in the calculator and change any input.
Formula
\(q = (\rho t + 2\rho_p t_p)g, \quad w = q\,h(1 - f_o)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(t\) | Wall thickness (without plaster) | m |
| \(h\) | Wall height | m |
| \(\rho\) | Masonry density | kg/m³ |
| \(t_p\) | Plaster thickness each face | m |
| \(\rho_p\) | Plaster density | kg/m³ |
| \(f_o\) | Openings as a share of wall area | - |
| \(w\) | Line load | N/m |
| \(q\) | Wall weight per square metre of face | Pa |
Method and standards
Wall load.
Where it is used
- Beam and slab design.
- Checking loads on existing structures.
Common mistakes
- Forgetting plaster.
- Deducting openings fully.
Assumptions and limits
- Uniform wall; unit weights as entered.
References
- Dead load from unit weights
Questions and answers
What load does a 230 mm brick wall 3 m high put on a beam?
About 14.4 kN/m with 12 mm plaster both faces.
Should openings be deducted?
Partly: lintels carry the load above openings to the jambs.
What do the defaults represent?
An illustrative 230 mm brick wall, 3 m high, density 1,920 kg/m³, with 12 mm plaster on each face and no openings.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.