Worked example
Example: A week at 15–25 °C, datum −10 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Datum temperature | -10.000 °C |
| Period 1 mean temperature | 15.000 °C |
| Period 1 duration | 24.000 h |
| Period 2 mean temperature | 20.000 °C |
| Period 2 duration | 48.000 h |
| Period 3 mean temperature | 25.000 °C |
| Period 3 duration | 96.000 h |
| Period 4 mean temperature | 10.000 °C |
| Period 4 duration | 0 h |
| Reference temperature | 20.000 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Maturity | 5,400.0 °C·h |
| Equivalent age at the reference temperature | 180.00 h |
| Actual age | 168.00 h |
Open this example in the calculator and change any input.
Formula
\(M = \sum \max(T - T_0,\,0)\,\Delta t, \quad t_e = \frac{M}{T_r - T_0}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(T_0\) | Datum temperature | K |
| \(T_1\) | Period 1 mean temperature | K |
| \(\Delta t_1\) | Period 1 duration | s |
| \(T_2\) | Period 2 mean temperature | K |
| \(\Delta t_2\) | Period 2 duration | s |
| \(T_3\) | Period 3 mean temperature | K |
| \(\Delta t_3\) | Period 3 duration | s |
| \(T_4\) | Period 4 mean temperature | K |
| \(\Delta t_4\) | Period 4 duration | s |
| \(T_r\) | Reference temperature | K |
| \(M\) | Maturity (°C·h) | - |
| \(t_e\) | Equivalent age at the reference temperature | s |
| \(t\) | Actual age | s |
Method and standards
Nurse–Saul function.
Where it is used
- Formwork stripping and post-tensioning times.
- Cold-weather concreting.
Common mistakes
- Using the wrong datum.
- Skipping the mix calibration curve.
Assumptions and limits
- Mean temperatures over each period; a period colder than the datum adds nothing (it is not counted as negative maturity).
- Maturity is always in °C·h, whatever the unit system.
References
- Nurse–Saul maturity function (ASTM C1074 principle; Neville, Properties of Concrete, ch. 6)
Questions and answers
Why does temperature matter?
Cement hydration speeds up when warm; concrete cured cold gains strength slowly.
When is formwork safe to strike?
When the maturity reaches the value at which the calibrated mix has the needed strength.
What do the defaults represent?
A week of curing at 15–25 °C with a −10 °C datum.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.