Worked example
Example: Small frame. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Column width | 0.30000 m |
| Column depth | 0.45000 m |
| Column height | 3.0000 m |
| Number of columns | 12.000 - |
| Beam width (soffit) | 0.23000 m |
| Beam depth below the slab (sides) | 0.33000 m |
| Total beam length (clear spans) | 90.000 m |
| Slab soffit area (less beam soffits) | 160.00 m² |
| Slab edge length | 56.000 m |
| Slab thickness | 0.15000 m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Columns (four sides) | 54.000 m² |
| Beams (soffit and two sides) | 80.100 m² |
| Slab soffit and edges | 168.40 m² |
| Total formwork area | 302.50 m² |
Open this example in the calculator and change any input.
Formula
\(A_c = 2(b_c + d_c) h_c n_c, \quad A_b = (b_b + 2 d_b) L_b, \quad A_{sl} = A_s + P_s t_s\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(b_c\) | Column width | m |
| \(d_c\) | Column depth | m |
| \(h_c\) | Column height | m |
| \(n_c\) | Number of columns | - |
| \(b_b\) | Beam width (soffit) | m |
| \(d_b\) | Beam depth below the slab (sides) | m |
| \(L_b\) | Total beam length (clear spans) | m |
| \(A_s\) | Slab soffit area (less beam soffits) | m² |
| \(P_s\) | Slab edge length | m |
| \(t_s\) | Slab thickness | m |
| \(A_c\) | Columns (four sides) | m² |
| \(A_b\) | Beams (soffit and two sides) | m² |
| \(A_{sl}\) | Slab soffit and edges | m² |
| \(A\) | Total formwork area | m² |
Method and standards
Contact areas.
Where it is used
- Formwork hire and labour estimates.
- Bills of quantities.
Common mistakes
- Counting beam sides within the slab.
- Using centre-line spans.
Assumptions and limits
- Rectangular members.
References
- Contact area of formwork (Common site practice (quantity estimating))
Questions and answers
Twelve 300 × 450 columns, 3 m high?
54 m² of column formwork.
Beams?
Soffit plus two sides below the slab, over the clear spans.
Is footing formwork included?
Add footing sides separately if they are shuttered.