RC Short Column Axial Load Capacity

Squash load, nominal and design axial capacity of a short reinforced concrete column with a factor for minimum eccentricity, and the steel area for a design load.

Inputs

Examples: Illustrative 400 x 400, 1.5 % steel, 2500 kN600 x 600 heavy column 8000 kNLight load, concrete suffices

Accepted: 10 to 100 MPa
Accepted: 200 to 700 MPa
Accepted: 100 to 3,000 mm
Accepted: 100 to 3,000 mm
Accepted: 10 to 100,000 mm²
Accepted: 0.4 to 1
Accepted: 50 to 100 %
Accepted: 30 to 100 %
Accepted: 0 to 100,000 kN

Results

P₀ = α₁f'_c(A_g − A_st) + f_yA_st. Valid for short, braced columns under nearly axial load; slender columns and real moments need an interaction diagram. Take k_e, φ and steel limits (usually 1–4 %) from your code; a zero steel area means concrete alone suffices and minimum steel governs.

Steel ratio1.5000%
Squash load5,026.8kN
Nominal capacity4,021.4kN
Design capacity2,613.9kN
Steel area for the design load1,844.6mm²

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 400 x 400, 1.5 % steel, 2500 kN. The inputs, in the units selected above:

InputValue
Concrete strength30.000 MPa
Steel yield strength420.00 MPa
Column width400.00 mm
Column depth400.00 mm
Longitudinal steel area2,400.0 mm²
Concrete stress factor0.85000 -
Factor for minimum eccentricity80.000 %
Strength reduction factor65.000 %
Design axial load2,500.0 kN

Applying the formula below gives:

ResultValue
Steel ratio1.5000 %
Squash load5,026.8 kN
Nominal capacity4,021.4 kN
Design capacity2,613.9 kN
Steel area for the design load1,844.6 mm²

Open this example in the calculator and change any input.

Formula

\(P_0 = \alpha_1f'_c(A_g - A_{st}) + f_yA_{st}, \quad \phi P_n = \phi k_eP_0\)

Variables

Symbol Meaning SI unit
\(f'_c\) Concrete strength Pa
\(f_y\) Steel yield strength Pa
\(b\) Column width m
\(h\) Column depth m
\(A_{st}\) Longitudinal steel area m²
\(\alpha_1\) Concrete stress factor -
\(k_e\) Factor for minimum eccentricity -
\(\phi\) Strength reduction factor -
\(P_u\) Design axial load N
\(\rho_g\) Steel ratio -
\(P_0\) Squash load N
\(P_n\) Nominal capacity N
\(\phi P_n\) Design capacity N
\(A_{st,req}\) Steel area for the design load m²

Method and standards

Axial capacity.

Where it is used

  • Building column design.
  • Checking existing columns for added load.

Common mistakes

  • Applying it to slender columns.
  • Forgetting to deduct steel area from concrete.

Assumptions and limits

  • Short braced column; concentric load.

References

  • Axial capacity of short tied columns

Questions and answers

What makes a column 'short'?

A low slenderness (effective length over radius of gyration), so second-order moments from deflection are negligible.

Why reduce the squash load?

Real columns always carry some eccentricity from construction tolerances; codes apply a factor or a minimum eccentricity.

What do the defaults represent?

An illustrative 400 × 400 mm tied column with 2,400 mm² of steel (1.5 %), f'_c 30 MPa and f_y 420 MPa, checked for a 2,500 kN design load.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Nawy, Reinforced Concrete: A Fundamental Approach, 6th ed. (Pearson, 2009), ch. 9

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.