FireCADCalc

Biaxially Loaded Column: Bresler Reciprocal Load Method

Axial capacity of a reinforced concrete column bent about both axes by Bresler's reciprocal load formula, from the uniaxial capacities at the same eccentricities.

Inputs

Examples: Illustrative corner columnNearly axialLarge eccentricities

Accepted: 1 to 1,000,000 kN
Accepted: 1 to 1,000,000 kN
Accepted: 1 to 1,000,000 kN
Accepted: 50 to 100 %
Accepted: 0 to 1,000,000 kN

Results

Bresler's reciprocal formula 1/P_n = 1/P_nx + 1/P_ny − 1/P_0 approximates the failure surface by a plane through the three points. It is accurate when the column is controlled by compression (P_n above about 0.1 f'_c A_g); for small axial loads use the load contour method instead. P_nx and P_ny come from the interaction diagram of each axis at the actual eccentricities.

Nominal biaxial capacity1,620.9kN
Design biaxial capacity1,053.6kN
Utilisation94.914%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative corner column. The inputs, in the units selected above:

InputValue
Axial capacity with no bending4,500.0 kN
Capacity with the x eccentricity alone2,600.0 kN
Capacity with the y eccentricity alone2,200.0 kN
Strength reduction factor65.000 %
Design axial load1,000.0 kN

Applying the formula below gives:

ResultValue
Nominal biaxial capacity1,620.9 kN
Design biaxial capacity1,053.6 kN
Utilisation94.914 %

Open this example in the calculator and change any input.

Formula

\(\frac1{P_n} = \frac1{P_{nx}} + \frac1{P_{ny}} - \frac1{P_0}\)

Variables

Symbol Meaning SI unit
\(P_0\) Axial capacity with no bending N
\(P_{nx}\) Capacity with the x eccentricity alone N
\(P_{ny}\) Capacity with the y eccentricity alone N
\(\phi\) Strength reduction factor -
\(P_u\) Design axial load N
\(P_n\) Nominal biaxial capacity N
\(\phi P_n\) Design biaxial capacity N
\(P_u/\phi P_n\) Utilisation -

Method and standards

Bresler method.

Where it is used

  • Corner columns with bending about both axes.
  • Checking columns with biaxial eccentricity.

Common mistakes

  • Using it for small axial loads.
  • Taking P_nx from the balanced point instead of the actual eccentricity.

Assumptions and limits

  • Compression-controlled section.

References

  • Bresler reciprocal load formula

Questions and answers

When is Bresler's method valid?

For compression-controlled columns, axial load above about 10 % of f'_c A_g.

Where do P_nx and P_ny come from?

From each axis's interaction diagram at the actual eccentricity e_x or e_y alone.

What do the defaults represent?

An illustrative column with P₀ = 4,500 kN, P_nx = 2,600 kN and P_ny = 2,200 kN, φ = 0.65, carrying 1,000 kN.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Bresler, Design criteria for reinforced columns under axial load and biaxial bending, ACI Journal 57 (1960)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.