FireCADCalc

Lintel Load from Masonry Arching (Triangular Load)

Load on a lintel from the masonry above, as the 60° equilateral triangle when arching can develop or the full rectangle otherwise, with moment and shear.

Inputs

Examples: Illustrative 1.8 m lintel, archingWide opening, little masonry aboveStone wall 1.2 m span

Accepted: 0.2 to 20 m
Accepted: 50 to 2,000 mm
Accepted: 5 to 30 kN/m³
Accepted: 0 to 50 m

Results

Masonry over an opening arches over it once mortar has set, so the lintel carries only the wedge of masonry under the arch, taken as an equilateral triangle on the span (sides at 60°, height L√3/2). The arch needs enough masonry above the triangle to develop; a common rule asks for about 1.25 times the triangle height. Otherwise the lintel carries the full rectangle of masonry up to that height. A triangular load W on a simple span gives M = WL/6; a uniform load gives WL/8. Floor or roof loads within the triangle, and openings close to the lintel ends, need separate checks.

Height of the equilateral load triangle1.5588m
Arching possible (1 = yes)1.0000
Total load on the lintel6.1309kN
Maximum bending moment1.8393kN·m
End shear3.0655kN

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 1.8 m lintel, arching. The inputs, in the units selected above:

InputValue
Effective span of the lintel1.8000 m
Wall thickness230.00 mm
Unit weight of masonry19.000 kN/m³
Height of masonry above the lintel2.4000 m

Applying the formula below gives:

ResultValue
Height of the equilateral load triangle1.5588 m
Arching possible (1 = yes)1.0000
Total load on the lintel6.1309 kN
Maximum bending moment1.8393 kN·m
End shear3.0655 kN

Open this example in the calculator and change any input.

Formula

\(h_t = \frac{\sqrt3}{2}L, \quad W = \tfrac12Lh_tt\gamma, \quad M = \frac{WL}{6}\)

Variables

Symbol Meaning SI unit
\(L\) Effective span of the lintel m
\(t\) Wall thickness m
\(\gamma\) Unit weight of masonry N/m³
\(h_w\) Height of masonry above the lintel m
\(h_t\) Height of the equilateral load triangle m
\(\text{arching}\) Arching possible (1 = yes) -
\(W\) Total load on the lintel N
\(M\) Maximum bending moment N·m
\(V\) End shear N

Method and standards

Lintel load.

Where it is used

  • Door and window lintels in load-bearing walls.
  • Checking precast lintel capacity.

Common mistakes

  • Taking full wall height when arching applies.
  • Ignoring floor loads inside the triangle.

Assumptions and limits

  • Simply supported lintel; uniform masonry; arching rule as stated.

References

  • Lintel loading with arching action

Questions and answers

Why only a triangle of masonry?

Above it the masonry arches and carries its weight to the supports beside the opening.

When does arching not form?

When there is too little masonry above, openings nearby, or the wall is not yet set (during construction).

What do the defaults represent?

An illustrative 1.8 m effective span in a 230 mm brick wall (19 kN/m³) with 2.4 m of masonry above.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Punmia, Jain and Jain, Building Construction, 11th ed. (Laxmi, 2016)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.