Worked example
Example: Illustrative 10 steps, 1.2 m wide. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Riser height | 150.00 mm |
| Tread (going) | 300.00 mm |
| Number of steps in the flight | 10.000 - |
| Stair width | 1.2000 m |
| Waist slab thickness | 150.00 mm |
| Landing length | 1.2000 m |
| Landing thickness | 150.00 mm |
| Steel per m³ of concrete | 90.000 kg/m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Sloping length of the flight | 3.3541 m |
| Waist slab concrete | 0.60374 m³ |
| Steps concrete | 0.27000 m³ |
| Total concrete (flight and landing) | 1.0897 m³ |
| Soffit formwork | 5.4649 m² |
| Reinforcement estimate | 98.076 kg |
Open this example in the calculator and change any input.
Formula
\(L_s = n\sqrt{R^2 + T^2}, \quad V = L_st_ww + n\tfrac12RTw + L_lt_lw\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(R\) | Riser height | m |
| \(T\) | Tread (going) | m |
| \(n\) | Number of steps in the flight | - |
| \(w\) | Stair width | m |
| \(t_w\) | Waist slab thickness | m |
| \(L_l\) | Landing length | m |
| \(t_l\) | Landing thickness | m |
| \(r_s\) | Steel per m³ of concrete | kg/m³ |
| \(L_s\) | Sloping length of the flight | m |
| \(V_w\) | Waist slab concrete | m³ |
| \(V_s\) | Steps concrete | m³ |
| \(V\) | Total concrete (flight and landing) | m³ |
| \(A_f\) | Soffit formwork | m² |
| \(m_s\) | Reinforcement estimate | kg |
Method and standards
Stair quantities.
Where it is used
- Estimating and billing of buildings.
- Checking contractor quantities.
Common mistakes
- Measuring the waist horizontally.
- Counting risers and treads inconsistently.
Assumptions and limits
- Straight flight; uniform steps.
References
- Quantity take-off of stair flights
- Standard quantity surveying practice
Questions and answers
Why is the waist measured on the slope?
The slab runs along the incline under the steps; its length is the hypotenuse of rise and going.
How much steel does a stair use?
Typically 80–110 kg per m³ of concrete for residential stairs.
What do the defaults represent?
An illustrative 1.2 m wide flight of ten 150 mm risers on 300 mm treads with a 150 mm waist and a 1.2 m landing.