Worked example
Example: 3.2 m floor. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Floor-to-floor height | 3.2000 m |
| Target riser height | 165.00 mm |
| Tread (going) per step | 270.00 mm |
Applying the formula below gives:
| Result | Value |
|---|---|
| Number of risers (rounded) | 19.000 |
| Actual riser height | 168.42 mm |
| Total going (n − 1) T | 4.8600 m |
| Comfort rule 2R + T | 606.84 mm |
| Pitch of the stair | 31.955 ° |
Open this example in the calculator and change any input.
Formula
\(n = \text{round}\left(\frac{H}{R_t}\right), \quad R = \frac{H}{n}, \quad G = (n - 1)T, \quad \tan\theta = \frac{R}{T}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(H\) | Floor-to-floor height | m |
| \(R_t\) | Target riser height | m |
| \(T\) | Tread (going) per step | m |
| \(n\) | Number of risers (rounded) | - |
| \(R\) | Actual riser height | m |
| \(G\) | Total going (n − 1) T | m |
| \(2R + T\) | Comfort rule 2R + T | m |
| \(\theta\) | Pitch of the stair | rad |
Method and standards
Geometry.
Where it is used
- Stair layout.
- Checking drawings.
Common mistakes
- Equal number of risers and treads.
- Ignoring the landing.
Assumptions and limits
- Straight flight.
- The number of risers is the nearest whole number, so the actual riser can be a little above the target; the page warns then, and when 2R + T is outside 550–700 mm.
References
- Blondel's rule 2R + T (comfort check)
Questions and answers
3.2 m floor height with about 165 mm risers?
19 risers of 168.4 mm; with 270 mm treads the going is 4.86 m.
Why n − 1 treads?
The top riser lands on the floor above.
What is 2R + T?
Blondel's comfort rule, about one stride.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.