Worked example
Example: Illustrative: 300 x 550 beam, 3 bars of 25 mm, d 500, 120 kN m. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Beam width | 300.00 mm |
| Effective depth | 500.00 mm |
| Tension steel area | 1,473.0 mm² |
| Steel modulus | 200.00 GPa |
| Concrete modulus | 25.000 GPa |
| Service bending moment | 120.00 kN·m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Modular ratio E_s/E_c | 8.0000 |
| Neutral axis depth (cracked) | 162.77 mm |
| Cracked moment of inertia | 177,137 cm⁴ |
| Lever arm d − x/3 | 445.74 mm |
| Maximum concrete compressive stress | 11.027 MPa |
| Steel tensile stress | 182.76 MPa |
| Steel ratio A_s/(bd) | 0.98200 % |
Open this example in the calculator and change any input.
Formula
\(\frac{bx^2}{2} = nA_s(d - x), \quad I_{cr} = \frac{bx^3}{3} + nA_s(d - x)^2, \quad f_c = \frac{Mx}{I_{cr}}, \quad f_s = \frac{nM(d - x)}{I_{cr}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(b\) | Beam width | m |
| \(d\) | Effective depth | m |
| \(A_s\) | Tension steel area | m² |
| \(E_s\) | Steel modulus | Pa |
| \(E_c\) | Concrete modulus | Pa |
| \(M\) | Service bending moment | N·m |
| \(n\) | Modular ratio E_s/E_c | - |
| \(x\) | Neutral axis depth (cracked) | m |
| \(I_{cr}\) | Cracked moment of inertia | m⁴ |
| \(jd\) | Lever arm d − x/3 | m |
| \(f_c\) | Maximum concrete compressive stress | Pa |
| \(f_s\) | Steel tensile stress | Pa |
| \(\rho\) | Steel ratio A_s/(bd) | - |
Method and standards
Transformed-section elastic analysis.
Where it is used
- Service stress and crack width checks, deflection with I_cr.
- Assessment of existing beams by working-stress methods.
Common mistakes
- Using gross section properties for a cracked beam.
- Comparing service stresses with ultimate strengths.
Assumptions and limits
- Plane sections remain plane, linear elastic materials, tension concrete cracked.
References
- Elastic cracked transformed-section analysis of a reinforced concrete beam
Questions and answers
Why is the concrete below the neutral axis ignored?
Under service loads the tension concrete has cracked; only the steel carries tension, with the concrete in compression above the neutral axis.
What modular ratio should I use?
E_s/E_c, typically 7–10 for short-term loads; long-term loads use a reduced (effective) concrete modulus, giving 15–20.
What do the defaults represent?
An illustrative 300 × 550 mm beam with 3 × 25 mm bars (1,473 mm²) at 500 mm effective depth carrying 120 kN·m.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Nilson, Darwin and Dolan, Design of Concrete Structures, 14th ed. (McGraw-Hill, 2010), ch. 3