FireCADCalc

Shear Reinforcement: Stirrup Spacing for a Design Shear

Stirrup spacing a concrete beam needs for a design shear by the 45° truss model, from the concrete's share, stirrup legs and steel, with the steel shear capacity.

Inputs

Examples: Illustrative beam, 350 kN shearFour-legged stirrups, high shearConcrete alone suffices

Accepted: 1 to 100,000 kN
Accepted: 0 to 100,000 kN
Accepted: 50 to 100 %
Accepted: 4 to 40 mm
Accepted: 1 to 12
Accepted: 200 to 700 MPa
Accepted: 100 to 3,000 mm
Accepted: 0 to 1,000 mm

Results

With 45° cracks each stirrup crossing a crack carries A_v f_yt, and d/s stirrups cross it, so V_s = A_v f_yt d / s. The stirrups must carry what the concrete cannot: V_s = V_u/φ − V_c. Codes also set a maximum spacing (often d/2), a minimum stirrup area and an upper limit on V_s: apply them from your code.

Stirrup area (all legs)157.08mm²
Shear the stirrups must carry316.67kN
Largest spacing for the design shear113.22mm
Steel shear capacity at the spacing provided239.02kN
Design shear capacity at the spacing provided291.77kN

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative beam, 350 kN shear. The inputs, in the units selected above:

InputValue
Design shear force350.00 kN
Shear carried by the concrete (from your code)150.00 kN
Strength reduction factor for shear75.000 %
Stirrup bar diameter10.000 mm
Number of stirrup legs2.0000 -
Stirrup yield strength415.00 MPa
Effective depth550.00 mm
Spacing provided (0 = skip check)150.00 mm

Applying the formula below gives:

ResultValue
Stirrup area (all legs)157.08 mm²
Shear the stirrups must carry316.67 kN
Largest spacing for the design shear113.22 mm
Steel shear capacity at the spacing provided239.02 kN
Design shear capacity at the spacing provided291.77 kN

Open this example in the calculator and change any input.

Formula

\(V_s = \frac{V_u}{\phi} - V_c, \quad s = \frac{A_v f_{yt} d}{V_s}\)

Variables

Symbol Meaning SI unit
\(V_u\) Design shear force N
\(V_c\) Shear carried by the concrete (from your code) N
\(\phi\) Strength reduction factor for shear -
\(\varnothing\) Stirrup bar diameter m
\(n\) Number of stirrup legs -
\(f_{yt}\) Stirrup yield strength Pa
\(d\) Effective depth m
\(s\) Spacing provided (0 = skip check) m
\(A_v\) Stirrup area (all legs) m²
\(V_s\) Shear the stirrups must carry N
\(s_{req}\) Largest spacing for the design shear m
\(V_s(s)\) Steel shear capacity at the spacing provided N
\(\phi(V_c + V_s)\) Design shear capacity at the spacing provided N

Method and standards

Stirrup spacing.

Where it is used

  • Beam shear design.
  • Checking existing stirrup layouts.

Common mistakes

  • Using one leg's area for a two-legged stirrup.
  • Ignoring the code's maximum spacing.

Assumptions and limits

  • Vertical stirrups; 45° truss model.

References

  • Truss model of shear with 45° cracks (V_s = A_v f_yt d/s)

Questions and answers

How is stirrup spacing calculated?

s = A_v f_yt d / V_s, with V_s = V_u/φ − V_c.

Why do codes limit spacing to d/2?

So that every 45° crack is crossed by at least one stirrup.

What do the defaults represent?

An illustrative beam with 350 kN design shear, 150 kN concrete share, 2-legged 10 mm stirrups of 415 MPa steel and d = 550 mm.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Nawy, Reinforced Concrete: A Fundamental Approach, 6th ed. (Pearson, 2009)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.