FireCADCalc

Reinforcement Development and Lap Length from Bond Stress

Development (anchorage) length of a reinforcing bar from bar diameter, the stress to develop and the design bond stress, with the lap length for a lap factor.

Inputs

Examples: Illustrative 16 mm deformed bar25 mm bar, 415 grade12 mm in compression

Accepted: 4 to 60 mm
Accepted: 50 to 800 MPa
Accepted: 0.5 to 10 MPa
Accepted: 1 to 2.5

Results

Force balance σ_s·πφ²/4 = τ_bd·πφ·L_d gives L_d = φσ_s/(4τ_bd). Codes raise bond stress for deformed bars and compression and lower it for top bars, coated bars or poor cover; enter the design bond stress your code gives.

Development length1,175.3mm
Development length in bar diameters47.012
Lap length1,527.9mm
Bar force developed177.23kN

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 16 mm deformed bar. The inputs, in the units selected above:

InputValue
Bar diameter16.000 mm
Stress to develop in the bar435.00 MPa
Design bond stress2.8000 MPa
Lap factor (lap / development length)1.3000 -

Applying the formula below gives:

ResultValue
Development length621.43 mm
Development length in bar diameters38.839
Lap length807.86 mm
Bar force developed87.462 kN

Open this example in the calculator and change any input.

Formula

\(L_d = \frac{\phi\sigma_s}{4\tau_{bd}}, \quad L_{lap} = k_lL_d\)

Variables

Symbol Meaning SI unit
\(\phi\) Bar diameter m
\(\sigma_s\) Stress to develop in the bar Pa
\(\tau_{bd}\) Design bond stress Pa
\(k_l\) Lap factor (lap / development length) -
\(L_d\) Development length m
\(L_d/\phi\) Development length in bar diameters -
\(L_{lap}\) Lap length m
\(F\) Bar force developed N

Method and standards

Bond anchorage.

Where it is used

  • Detailing beams, columns and slabs.
  • Checking bar curtailment.

Common mistakes

  • Using plain-bar bond stress for deformed bars, or the reverse.
  • Forgetting the lap factor in tension.

Assumptions and limits

  • Uniform bond stress along the bar.

References

  • Bond force balance for anchorage

Questions and answers

Why do larger bars need longer anchorage?

Force grows with the bar's area (φ²) but bond acts on its perimeter (φ), so length grows with φ.

Is the lap length always longer?

Usually; laps in tension zones with many bars spliced at one section need longer lengths.

What do the defaults represent?

An illustrative 16 mm deformed bar developing 0.87 × 500 MPa with a design bond stress of 2.8 MPa, lap factor 1.3.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Punmia, Jain and Jain, Reinforced Concrete Structures (Laxmi, 2006)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.