Worked example
Example: Illustrative 400 x 400, 1.5 % steel, 2500 kN. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Concrete strength | 30.000 MPa |
| Steel yield strength | 420.00 MPa |
| Column width | 400.00 mm |
| Column depth | 400.00 mm |
| Longitudinal steel area | 2,400.0 mm² |
| Concrete stress factor | 0.85000 - |
| Factor for minimum eccentricity | 80.000 % |
| Strength reduction factor | 65.000 % |
| Design axial load | 2,500.0 kN |
Applying the formula below gives:
| Result | Value |
|---|---|
| Steel ratio | 1.5000 % |
| Squash load | 5,026.8 kN |
| Nominal capacity | 4,021.4 kN |
| Design capacity | 2,613.9 kN |
| Steel area for the design load | 1,844.6 mm² |
Open this example in the calculator and change any input.
Formula
\(P_0 = \alpha_1f'_c(A_g - A_{st}) + f_yA_{st}, \quad \phi P_n = \phi k_eP_0\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(f'_c\) | Concrete strength | Pa |
| \(f_y\) | Steel yield strength | Pa |
| \(b\) | Column width | m |
| \(h\) | Column depth | m |
| \(A_{st}\) | Longitudinal steel area | m² |
| \(\alpha_1\) | Concrete stress factor | - |
| \(k_e\) | Factor for minimum eccentricity | - |
| \(\phi\) | Strength reduction factor | - |
| \(P_u\) | Design axial load | N |
| \(\rho_g\) | Steel ratio | - |
| \(P_0\) | Squash load | N |
| \(P_n\) | Nominal capacity | N |
| \(\phi P_n\) | Design capacity | N |
| \(A_{st,req}\) | Steel area for the design load | m² |
Method and standards
Axial capacity.
Where it is used
- Building column design.
- Checking existing columns for added load.
Common mistakes
- Applying it to slender columns.
- Forgetting to deduct steel area from concrete.
Assumptions and limits
- Short braced column; concentric load.
References
- Axial capacity of short tied columns
Questions and answers
What makes a column 'short'?
A low slenderness (effective length over radius of gyration), so second-order moments from deflection are negligible.
Why reduce the squash load?
Real columns always carry some eccentricity from construction tolerances; codes apply a factor or a minimum eccentricity.
What do the defaults represent?
An illustrative 400 × 400 mm tied column with 2,400 mm² of steel (1.5 %), f'_c 30 MPa and f_y 420 MPa, checked for a 2,500 kN design load.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Nawy, Reinforced Concrete: A Fundamental Approach, 6th ed. (Pearson, 2009), ch. 9