FireCADCalc

Reinforced Concrete Beam: Cracked Transformed Section Stresses

Neutral axis depth, cracked moment of inertia, lever arm and the concrete and steel stresses of a singly reinforced rectangular concrete beam under service moment.

Inputs

Examples: Illustrative: 300 x 550 beam, 3 bars of 25 mm, d 500, 120 kN mSlab strip 1000 mm wide, d 150, 12 mm at 150 (754 mm2), 25 kN mHeavily reinforced 400 x 750, d 690, 4 x 32 mm, 450 kN m, long-term n 15

Accepted: 50 to 5,000 mm
Accepted: 50 to 5,000 mm
Accepted: 1 to 100,000 mm²
Accepted: 100 to 250 GPa
Accepted: 1 to 60 GPa
Accepted: 0 to 100,000 kN·m

Results

Elastic cracked-section analysis: concrete in tension ignored, linear stress in the compression zone, steel transformed by n. Used for service stresses, crack control and deflection (I_cr); not an ultimate-strength design check.

Modular ratio E_s/E_c8.0000
Neutral axis depth (cracked)162.77mm
Cracked moment of inertia177,137cm⁴
Lever arm d − x/3445.74mm
Maximum concrete compressive stress11.027MPa
Steel tensile stress182.76MPa
Steel ratio A_s/(bd)0.98200%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative: 300 x 550 beam, 3 bars of 25 mm, d 500, 120 kN m. The inputs, in the units selected above:

InputValue
Beam width300.00 mm
Effective depth500.00 mm
Tension steel area1,473.0 mm²
Steel modulus200.00 GPa
Concrete modulus25.000 GPa
Service bending moment120.00 kN·m

Applying the formula below gives:

ResultValue
Modular ratio E_s/E_c8.0000
Neutral axis depth (cracked)162.77 mm
Cracked moment of inertia177,137 cm⁴
Lever arm d − x/3445.74 mm
Maximum concrete compressive stress11.027 MPa
Steel tensile stress182.76 MPa
Steel ratio A_s/(bd)0.98200 %

Open this example in the calculator and change any input.

Formula

\(\frac{bx^2}{2} = nA_s(d - x), \quad I_{cr} = \frac{bx^3}{3} + nA_s(d - x)^2, \quad f_c = \frac{Mx}{I_{cr}}, \quad f_s = \frac{nM(d - x)}{I_{cr}}\)

Variables

Symbol Meaning SI unit
\(b\) Beam width m
\(d\) Effective depth m
\(A_s\) Tension steel area m²
\(E_s\) Steel modulus Pa
\(E_c\) Concrete modulus Pa
\(M\) Service bending moment N·m
\(n\) Modular ratio E_s/E_c -
\(x\) Neutral axis depth (cracked) m
\(I_{cr}\) Cracked moment of inertia m⁴
\(jd\) Lever arm d − x/3 m
\(f_c\) Maximum concrete compressive stress Pa
\(f_s\) Steel tensile stress Pa
\(\rho\) Steel ratio A_s/(bd) -

Method and standards

Transformed-section elastic analysis.

Where it is used

  • Service stress and crack width checks, deflection with I_cr.
  • Assessment of existing beams by working-stress methods.

Common mistakes

  • Using gross section properties for a cracked beam.
  • Comparing service stresses with ultimate strengths.

Assumptions and limits

  • Plane sections remain plane, linear elastic materials, tension concrete cracked.

References

  • Elastic cracked transformed-section analysis of a reinforced concrete beam

Questions and answers

Why is the concrete below the neutral axis ignored?

Under service loads the tension concrete has cracked; only the steel carries tension, with the concrete in compression above the neutral axis.

What modular ratio should I use?

E_s/E_c, typically 7–10 for short-term loads; long-term loads use a reduced (effective) concrete modulus, giving 15–20.

What do the defaults represent?

An illustrative 300 × 550 mm beam with 3 × 25 mm bars (1,473 mm²) at 500 mm effective depth carrying 120 kN·m.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Nilson, Darwin and Dolan, Design of Concrete Structures, 14th ed. (McGraw-Hill, 2010), ch. 3

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.