FireCADCalc

Punching Shear around a Column in a Flat Slab

Critical perimeter and punching shear stress around an interior, edge or corner column in a slab, the ratio to an allowable stress and the depth needed.

Inputs

Examples: Illustrative interior column 600 kNEdge column 350 kNCorner column 200 kN

Accepted: 1 to 100,000 kN
Accepted: 100 to 3,000 mm
Accepted: 100 to 3,000 mm
Accepted: 50 to 2,000 mm
Accepted: 0.1 to 10 MPa

Results

Critical section d/2 from the column faces: interior b₀ = 2(c₁ + c₂) + 4d, edge 2c₁ + c₂ + 2d, corner c₁ + c₂ + d. Unbalanced moments at edge and corner columns raise the peak stress well above V/(b₀d); take allowable stress and moment transfer rules from your code.

Critical perimeter at d/2880.00mm
Shear stress1.2626MPa
Utilisation97.125%
Effective depth needed175.69mm

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative interior column 600 kN. The inputs, in the units selected above:

InputValue
Column positionInterior
Punching shear force600.00 kN
Column dimension c₁400.00 mm
Column dimension c₂ (along the edge)400.00 mm
Slab effective depth200.00 mm
Allowable punching shear stress1.4000 MPa

Applying the formula below gives:

ResultValue
Critical perimeter at d/22,400.0 mm
Shear stress1.2500 MPa
Utilisation89.286 %
Effective depth needed183.59 mm

Open this example in the calculator and change any input.

Formula

\(b_0 = A + Bd, \quad v = \frac{V}{b_0d}, \quad d_{req} = \frac{-Av_c + \sqrt{A^2v_c^2 + 4Bv_cV}}{2Bv_c}\)

Variables

Symbol Meaning SI unit
\(\text{pos}\) Column position -
\(V\) Punching shear force N
\(c_1\) Column dimension c₁ m
\(c_2\) Column dimension c₂ (along the edge) m
\(d\) Slab effective depth m
\(v_c\) Allowable punching shear stress Pa
\(b_0\) Critical perimeter at d/2 m
\(v\) Shear stress Pa
\(v/v_c\) Utilisation -
\(d_{req}\) Effective depth needed m

Method and standards

Punching perimeter.

Where it is used

  • Flat slab and footing design.
  • Checking slabs for added loads.

Common mistakes

  • Ignoring moment transfer at edge columns.
  • Using overall slab thickness for d.

Assumptions and limits

  • Rectangular column; no openings near the column.

References

  • Two-way (punching) shear at a critical perimeter

Questions and answers

Why is punching dangerous?

It is a brittle failure that can trigger progressive collapse of flat slabs; it gives little warning.

How can punching capacity be raised?

Thicker slab or drop panel, larger column or capital, shear studs, or higher concrete strength.

What do the defaults represent?

An illustrative interior 400 × 400 mm column carrying 600 kN punching shear through a slab of 200 mm effective depth, allowable 1.4 MPa.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Nawy, Reinforced Concrete: A Fundamental Approach, 6th ed. (Pearson, 2009), ch. 11

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.