Prestressed Concrete Beam: Stresses at Transfer and Service

Top and bottom fibre stresses of a prestressed concrete beam at transfer and in service from prestress, eccentricity, losses and the applied moments.

Inputs

Examples: Illustrative post-tensioned beamPre-tensioned hollow-core slab stripBridge girder

Accepted: 0.001 to 1,000,000 kN
Accepted: 0 to 60 %
Accepted: -5,000 to 5,000 mm
Accepted: 0.001 to 100 m²
Accepted: 1 to 10,000,000 cm³
Accepted: 1 to 10,000,000 cm³
Accepted: 0 to 1,000,000 kN·m
Accepted: 0 to 1,000,000 kN·m

Results

With compression positive, a prestress P at eccentricity e below the centroid gives P/A ∓ Pe/Z at the top and bottom fibres, and a sagging moment M adds ±M/Z. At transfer the full initial force acts with only the self-weight moment, so the top fibre risks tension and the bottom fibre high compression; in service the force has fallen by the losses and the full moment acts, so the bottom fibre risks tension. Compare the four stresses with the permissible limits of the design code for each stage.

Top fibre at transfer (compression positive)2.9458MPa
Bottom fibre at transfer11.784MPa
Top fibre in service15.629MPa
Bottom fibre in service-6.7949MPa
Effective prestress after losses3,600.0kN

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative post-tensioned beam. The inputs, in the units selected above:

InputValue
Initial prestress force (at transfer)1,200.0 kN
Long-term losses18.000 %
Tendon eccentricity below the centroid250.00 mm
Section area0.18000 m²
Section modulus, top fibre28,000 cm³
Section modulus, bottom fibre24,000 cm³
Moment at transfer (self-weight)150.00 kN·m
Total service moment520.00 kN·m

Applying the formula below gives:

ResultValue
Top fibre at transfer (compression positive)1.3095 MPa
Bottom fibre at transfer12.917 MPa
Top fibre in service15.252 MPa
Bottom fibre in service-5.9500 MPa
Effective prestress after losses984.00 kN

Open this example in the calculator and change any input.

Formula

\(f = \frac PA \mp \frac{Pe}{Z_t} \pm \frac{M}{Z_t} \;\text{(top)}, \quad f = \frac PA \pm \frac{Pe}{Z_b} \mp \frac{M}{Z_b} \;\text{(bottom)}\)

Variables

Symbol Meaning SI unit
\(P_i\) Initial prestress force (at transfer) N
\(\eta_L\) Long-term losses -
\(e\) Tendon eccentricity below the centroid m
\(A\) Section area m²
\(Z_t\) Section modulus, top fibre m³
\(Z_b\) Section modulus, bottom fibre m³
\(M_g\) Moment at transfer (self-weight) N·m
\(M_s\) Total service moment N·m
\(f_{t,i}\) Top fibre at transfer (compression positive) Pa
\(f_{b,i}\) Bottom fibre at transfer Pa
\(f_{t,s}\) Top fibre in service Pa
\(f_{b,s}\) Bottom fibre in service Pa
\(P_e\) Effective prestress after losses N

Method and standards

Prestress stresses.

Where it is used

  • Preliminary design of prestressed beams and slabs.
  • Checking transfer and service limits.

Common mistakes

  • Using the effective force at transfer.
  • Mixing tension-positive and compression-positive conventions.

Assumptions and limits

  • Uncracked elastic section; gross section properties; straight tendon at the section.

References

  • Elastic fibre stresses of prestressed members

Questions and answers

Why check both transfer and service?

At transfer prestress is highest and load lowest; in service the opposite. Each stage governs a different fibre.

What losses should I assume?

Typically 15–25 % for post-tensioned and 20–30 % for pre-tensioned members, from elastic shortening, creep, shrinkage, relaxation and friction.

What do the defaults represent?

An illustrative 1,200 kN prestress with 18 % losses at 250 mm eccentricity on a 0.18 m² section, with 150 and 520 kN·m moments.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Lin and Burns, Design of Prestressed Concrete Structures, 3rd ed. (Wiley, 1981)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.