Worked example
Example: Illustrative 1.8 m lintel, arching. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Effective span of the lintel | 1.8000 m |
| Wall thickness | 230.00 mm |
| Unit weight of masonry | 19.000 kN/m³ |
| Height of masonry above the lintel | 2.4000 m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Height of the equilateral load triangle | 1.5588 m |
| Arching possible (1 = yes) | 1.0000 |
| Total load on the lintel | 6.1309 kN |
| Maximum bending moment | 1.8393 kN·m |
| End shear | 3.0655 kN |
Open this example in the calculator and change any input.
Formula
\(h_t = \frac{\sqrt3}{2}L, \quad W = \tfrac12Lh_tt\gamma, \quad M = \frac{WL}{6}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(L\) | Effective span of the lintel | m |
| \(t\) | Wall thickness | m |
| \(\gamma\) | Unit weight of masonry | N/m³ |
| \(h_w\) | Height of masonry above the lintel | m |
| \(h_t\) | Height of the equilateral load triangle | m |
| \(\text{arching}\) | Arching possible (1 = yes) | - |
| \(W\) | Total load on the lintel | N |
| \(M\) | Maximum bending moment | N·m |
| \(V\) | End shear | N |
Method and standards
Lintel load.
Where it is used
- Door and window lintels in load-bearing walls.
- Checking precast lintel capacity.
Common mistakes
- Taking full wall height when arching applies.
- Ignoring floor loads inside the triangle.
Assumptions and limits
- Simply supported lintel; uniform masonry; arching rule as stated.
References
- Lintel loading with arching action
Questions and answers
Why only a triangle of masonry?
Above it the masonry arches and carries its weight to the supports beside the opening.
When does arching not form?
When there is too little masonry above, openings nearby, or the wall is not yet set (during construction).
What do the defaults represent?
An illustrative 1.8 m effective span in a 230 mm brick wall (19 kN/m³) with 2.4 m of masonry above.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Punmia, Jain and Jain, Building Construction, 11th ed. (Laxmi, 2016)